20LTR HFC-227ea cylinder fire suppression system

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 21:08

Other Products
Saddle type water flow indicator
¥Negotiable 11Views

Saddle type water flow indic

Recommend  
Reflective Safety Vest for Dog use
¥Negotiable 8Views

Reflective Safety Vest for D

Recommend  
Top 10 Polyester Fabric Crossfit Wholesale Safety Vest
¥Negotiable 9Views

Top 10 Polyester Fabric Cros

Recommend  
1.3KG 75% SUPER  FIRE BALL EXTINGUISHER AUTOMATIC
¥Negotiable 12Views

1.3KG 75% SUPER FIRE BALL E

Recommend  
emergency eye wash station
¥Negotiable 10Views

emergency eye wash station

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
welfare
Cylinder capacity:
20Ltr
Flexible hose material:
Stainless Steel
Pressure switch material:
brass
Stored pressure:
2.5MPA
Solenoid valve:
24dvc
Discharge time:
≤10s
Filling density:
≤950kg/m3
System working temperature:
-10℃~55℃
Supply Ability
Supply Ability:
1000 Set/Sets per Month
Packaging & Delivery
Packaging Details
wooden case
Port
Guangzhou or Shenzhen
Picture Example:
package-img
Lead Time:
Quantity(Sets)1 - 1 >1
Est. Time(days)7To be negotiated
Product Description

 

Company Information

 

FAQ

 

HFC-227ea is a clean extinguishing agent, which would completely vaporized in the air, and well insulated. Its total flooding mode is applicable to electric fire, liquid fire or fusible solid fire, solid surface fire, gas fire which gas supply is cut before extinguishing. And it is able to protect computer rooms, communication rooms, substation rooms, hi-tech device rooms, generator rooms, gasoline storerooms, combustible chemical storerooms, libraries, data rooms, archives, treasuries, etc. We manufacture HFC-227ea system that is well structured, reliable, and widely applied to computer rooms, archives, program control exchange engine rooms , TV broadcast center, financial organizations and government departments.


Volume:20L; 
Accessories: tank / valve/ internal siphon tube/pressure gauge/solenoid valve/flexible hose/liquid one way valve; Tank size:260*540*4mm(diameter*height*thickness); 
Material: magamest steel; 
Necking: M58X4; 
Painting: red epoxy polyster RAL3000/red coating polyster RAL3000; Valve size:brass,1";operated by safety release device (burst disc); Gauge: NPT 1/8;Eletrical acutuator: 24DCV; 
Filling pressure:4.2 Mpa or 2.5Mpa; 
Discharge time:≤10s; 
Filling density:≤950kg/m3; 
System working power: AC 220V DC 24V 1A 
System working temperature:-10
~55
Max protected area: max 800m2,max volume 3600m3; 
Operate: manual, auto and eletrical

 

NAMEMODELQTY/CTNN.W/CTNG.W/CTNCBM/CTNPacking size
DESCRIPTIONS pcskgkgM3CM
20ltr HFC-227ea CYLINDER+Valve+Solenoid 24DCV+Pressure gauge+Diptube+Flexible Hose +liquid valve +pressure switchZM-20L246.0070.000.245177*33*42


System Maintenance

1 The gas extinguishing system should be maintenance regularly by the people who received special training and pass the test.
2 Before the formal demonstration of system, the following documents must be prepared:
2.1 All of the technical information documentation and the report of inspection.
2.2 Regulations for technical operations
2.3 The inspection and maintenance record of the system.
3 The gas extinguishing system should be inspected twice a month. The detail requirements are as follow:
3.1 observational check of the extinguishing agent container, selector valve, liquid non-return valve, high-pressure tube, header pipe, valve driver, pipe system and nozzle. These system components shouldn’t be damaged due to collision or mechanical damage. The surface shouldn’t have rusty and the protection coating should be in perfect condition. The product plate should be visualized. The protect shell, lead seal and the safety sign should be in good shape.
3.2 The pressure of the cylinder shouldn’t be less than 3.8Mpa(4.2Mpa working pressure) or 2.3 Mpa (2.5Mpa working pressure). The pressure of the driving device shouldn’t be less than 5.0Mpa
4 The gas extinguishing system should be inspected thoroughly twice a year. The detail requirements are as follow:
4.1 The gate of the fire protective area, the usage of the protective area and the type of fuel, quantity and distribution situation should follow the requirements of the designs.
4.2 The equipment of the extinguishing agent container storage room, the extinguishing agent delivery pipe, piping support and hanger should be fixed without loose. 
4.3 The high-pressure tube: should in good shape without cracking and aging. If necessary, should test the water pressure strength and pressure tightness of the gas pressure of each high-pressure tube. 
4.4 The nozzle orifice shouldn’t be jammed.
4.5 If the extinguishing agent transportation pipe was damaged or jammed. It should be test the pressure tightness and flushed.
4.6 For each fire protection area should execute an automatic activating simulation test. If there are any parts failed, please execute an gas jetting simulation

 