Temperature control range:-50℃~110℃
Temperature measurement error:±0.5℃
Sensor model:NTC(10K/3435)
Control precision:1℃
Measurement error:±0.5℃
Working temperature:DC12V/DC24V/AC220V
Working current:MAX200mA
Relay contact current:AC5A/220V
Data storage:available
Working temperature:0℃~50℃
Storage temperature:-10℃~60℃
Product dimension:90mm(L)*60mm(W)*26.5mm(H)
Port size:70mm(L)*50mm(H)
Menu code introduction
Menu code | Detail explanation | Explanation | Unit |
HC | Heating/Cooling | Working mode set | H=Heating,C=Cooling |
D | Return difference | Temperature difference between the Power-on and shutoff | ℃ |
LS | Set the lower limit | Min value of control temperature set | ℃ |
HS | Set the upper limit | Max value of temperature set | ℃ |
CA | Temperature correction | | ℃ |
PT | Delay start | Min time interval of shutoff | ℃ |
AH | AL-H | AL-H | ℃ |
AL | AL-L | AL-L | ℃ |
Temperature controller set:Press"SET"one time,press three minutes to enter into setting menu after displayed flashing and displaying code HC then.
Heating mode:Set mode control mode(code HC) as H,it is heating mode
Such as set value of control heating as 35℃,temperature return difference is 2 °.When value of temperature ≤setting value(35℃)-difference return(2℃)relay start input at 33℃
Environment temperature≥setting temperature (35℃)relay start output
Cooling mode:set mode control way(code HC) as C,it is cooling mode.
For example,set cooling temperature as 35℃,return difference is 2°.When value of temperature ≥setting temperature value (35℃)+return difference(2℃)37℃ relay will start output
When environment temperature value ≤setting humidity value(35℃) relay will close output
HC:Mode selection,C means cooling mode,H means heating mode
D:Return difference,when temperature starting in heating mode=displaying temperature-return difference.when temperature starting in cooling mode=displaying temperature+ return difference
D:return difference ,when temperature starting in heating mode=displaying temperature-return difference,when temperature starting in cooling mode=displaying temperature+return difference
PU:Delay start,when relay start timing at relay stop output,the next starting time interval must greater than delay start time to avoid frequent startup.
HS:Temperature upper limit alarm;when temperature exceed high alarm setting,digital tube showing "HHH",when temperature lower than alarm setting value,it will exist automatically.
LS:Temperature lower limit alarm:when temperature exceed low alarm setting,digital tube showing "LLL"temperature higher than alarm setting value ,it will exist automatically
CA temperature correction:temperature correction value add into humidity value,for example:temperature displaying 35℃ calibration temperature increase 5℃,displaying temperature should be 40℃
Restoration:Press up and down keyboard on the left,screen displaying 888,it will restore factory setting
PT:Delay to start ,For example:delay time for 1 minutes,when temperature reached at setting value,relay will start up after delay on 1 minutes.
AH:High temperature alarm:For example:Set ultra high temperature alarm temperature at 50°,buzzer alarming when temperature higher than 50°
AL:Low-temperature warning:For example:set low temperature alarm temperature at 20℃,buzzer alarming when temperature lower than 20°
Time control code instruction
Code instruction | Detailed description | Explain | Unit | Factory reset |
PO | ON/OFF | Timer open and timer close | | ON |
P1 | Group 1 time open | Group 1 timing start time setting | H | 8:00:00 |
P2 | Group 1 time close | Group 1 timing close time closing | H | 10:00:00 |
P3 | Group 2 time open | Group 2 timing start time setting | H | 8:00:00 |
P4 | Group 2 time close | Group 2 timing close time setting | H | 10:00:00 |
P5 | Group 3 time open | Group 3 timing start time setting | H | 8:00:00 |
P6 | Group 3 time close | Group 3 timing close time setting | H | 10:00:00 |
P7 | ON/OFF | Time end of alarming and alarm turn off set | | OFF |
Set the time:Press the "SET"keyboard two time,then press three seconds after digital tube shows flashing and enter into set menu,it is displaying code"PO".
Time control:set the way of mode control PO as (ON) open type control mode.
P1:Group 1 time power-on set.For example,set up time at 8:00,temperature controller start working when time is equal or greater than 8:00
P2:Group 2 time shutdown set.For example,set up time at 10:00,temperature controller stop working when time is equal or greater than 10:00
P3:Group 3 time power-on set.For example,set up time at at 11:00,temperature controller start working when time is equal or greater than 11:00
P4:Group 4 time shutdown set.For example,set up time at 13:00,temperature controller stop working when time is equal or greater than 13:00.
P5:Group 5 time power-on set.For example,set up time at 18:00,temperature controller starts
working when time is equal or greater than 18:00.
P6:Group 3 time shutdown set.For example,set up time at 20:00,temperature controller start working when time is equal or greater than 20:00
P7:Time end alarm,for example,set the work time at 8:00 to 10:00,buzzer start alarming when time exceed 10:00