220v 12v 24v Timing timer temperature controller Thermostat Regulator control Time Switch Sensor, ZFX-W3020 Temperature Control

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-11-19 19:17

  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Branch:

Array

Size:

5X5X5 cm

Product Details

Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
taxnele
Model Number:
Humidity Controller
Product name:
Digital Temperature And Humidity Controller
Color:
as pic
Application:
Widely
Accuracy:
0.1%
Material:
Plastic
Power supply:
220VAC
Display:
Digital
Output:
relay SSR
Warranty:
18 months
Weight:
0.3kg

Packaging & Delivery

Selling Units:
Single item
Single package size: 
5X5X5 cm
Single gross weight:
0.15 kg
Package Type:
PAPER PACKING
Lead Time:
Quantity(Piece)1 - 100>100
Est. Time(days)7To be negotiated
parameters

NAMEZFX-W3020 timer temperature controller
 

Temperature control range:-50℃~110℃

Temperature measurement error:±0.5℃

Sensor model:NTC(10K/3435)

Control precision:1℃

Measurement error:±0.5℃

Working temperature:DC12V/DC24V/AC220V

Working current:MAX200mA

Relay contact current:AC5A/220V

Data storage:available

Working temperature:0℃~50℃

Storage temperature:-10℃~60℃

Product dimension:90mm(L)*60mm(W)*26.5mm(H)

Port size:70mm(L)*50mm(H)

Menu code introduction

 

Menu code

Detail explanation

Explanation

Unit

HC

Heating/Cooling

Working mode set

H=Heating,C=Cooling

D

Return difference

Temperature difference between the Power-on and shutoff

LS

Set the lower limit

Min value of control temperature set

HS

Set the upper limit

Max value of temperature set

CA

Temperature correction

 

PT

Delay start

Min time interval of shutoff

AH

AL-H

AL-H

AL

AL-L

AL-L

 

 

Temperature controller set:Press"SET"one time,press three minutes to enter into setting menu after displayed flashing and displaying code HC then.

 

Heating mode:Set mode control mode(code HC) as H,it is heating mode

Such as set value of control heating as 35℃,temperature return difference is 2 °.When value of temperature ≤setting value(35℃)-difference return(2℃)relay start input at 33℃

Environment temperature≥setting temperature (35℃)relay start output

Cooling mode:set mode control way(code HC) as C,it is cooling mode.

For example,set cooling temperature as 35℃,return difference is 2°.When value of temperature ≥setting temperature value (35℃)+return difference(2℃)37℃ relay will start output

When environment temperature value ≤setting humidity value(35℃) relay will close output

HC:Mode selection,C means cooling mode,H means heating mode

D:Return difference,when temperature starting in heating mode=displaying temperature-return difference.when temperature starting in cooling mode=displaying temperature+ return difference

D:return difference ,when temperature starting in heating mode=displaying temperature-return difference,when temperature starting in cooling mode=displaying temperature+return difference

PU:Delay start,when relay start timing at relay stop output,the next starting time interval must greater than delay start time to avoid frequent startup.

HS:Temperature upper limit alarm;when temperature exceed high alarm setting,digital tube showing "HHH",when temperature lower than alarm setting value,it will exist automatically.

LS:Temperature lower limit alarm:when temperature exceed low alarm setting,digital tube showing "LLL"temperature higher than alarm setting value ,it will exist automatically

CA temperature correction:temperature correction value add into humidity value,for example:temperature displaying 35℃ calibration temperature increase 5℃,displaying temperature should be 40℃

Restoration:Press up and down keyboard on the left,screen displaying 888,it will restore factory setting

PT:Delay to start ,For example:delay time for 1 minutes,when temperature reached at setting value,relay will start up after delay on 1 minutes.

AH:High temperature alarm:For example:Set ultra high temperature alarm temperature at 50°,buzzer alarming when temperature higher than 50°

AL:Low-temperature warning:For example:set low temperature alarm temperature at 20℃,buzzer alarming when temperature lower than 20°

 

Time control code instruction

Code instruction

Detailed description

Explain

Unit

Factory reset

PO

ON/OFF

Timer open and timer close

 

ON

P1

Group 1 time open

Group 1 timing start time setting

H

8:00:00

P2

Group 1 time close

Group 1 timing close time closing

H

10:00:00

P3

Group 2 time open

Group 2 timing start time setting

H

8:00:00

P4

Group 2 time close

Group 2 timing close time setting

H

10:00:00

P5

Group 3  time open

Group 3 timing start time setting

H

8:00:00

P6

Group 3 time  close

Group 3 timing close time setting

H

10:00:00

P7

ON/OFF

Time end of alarming and alarm turn off set

 

OFF

 

 

Set the time:Press the "SET"keyboard two time,then press three seconds after digital tube shows flashing and enter into set menu,it is displaying code"PO".

 

Time control:set the way of mode control PO as (ON) open type control mode.

P1:Group 1 time power-on set.For example,set up time at 8:00,temperature controller start working when time is equal or greater than 8:00

P2:Group 2 time shutdown set.For example,set up time at 10:00,temperature controller stop working when time is equal or greater than 10:00

P3:Group 3 time power-on set.For example,set up time at at 11:00,temperature controller start working when time is equal or greater than 11:00

P4:Group 4 time shutdown set.For example,set up time at 13:00,temperature controller stop working when time is equal or greater than 13:00.

P5:Group 5 time power-on set.For example,set up time at 18:00,temperature controller starts

working when time is equal or greater than 18:00.

P6:Group 3 time shutdown set.For example,set up time at 20:00,temperature controller start working when time is equal or greater than 20:00

P7:Time end alarm,for example,set the work time at 8:00 to 10:00,buzzer start alarming when time exceed 10:00

 
 
Product display

 

Company profile

 

Shopping notice

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links