3 Phase High Frequency 20KW 30KW 40KW 50KW 100KW 120KW Off Grid inverter for Solar Energy System

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Batteries
  • Validity Period:

    Long Term

  • Published on:

    2021-12-28 12:26

Other Products
On grid tie solar inverter growatt 50kW 60kw 70kw 80kw MPPT inverters for solar panel energy system power plant
¥Negotiable 117Views

On grid tie solar inverter g

Recommend  
3 Years Warranty Lead Carbon 12V 2V 100Ah 200Ah 400Ah 600Ah VRLA Gel Lead Acid Battery
¥Negotiable 68Views

3 Years Warranty Lead Carbon

Recommend  
Lovsun VRLA Solar GEL Battery 2V 200AH 400 ah Opzv With Factory Price
¥Negotiable 106Views

Lovsun VRLA Solar GEL Batter

Recommend  
Deep Cycle OPZV Lead-acid Solar Gel Battery 2V 1000ah 1500ah 2000ah Solar Battery
¥Negotiable 99Views

Deep Cycle OPZV Lead-acid So

Recommend  
Tier 1 Trina Vertex 490w 500w 510w Solar Panel 485w 495w 505w Half Cut Cells Monocrystalline PV Module
¥Negotiable 56Views

Tier 1 Trina Vertex 490w 500

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Product Description
GF10-120KVA Off Grid Solar Inverter

●High-speed DSP digital control
●Full-bridge inverter control technology, providing secure power supply in the event of threephase 100% unbalanced loads
●Multi-string PV connected
●Inbuilt AC rectifier and MPPT control modules, configured battery parameters by operating interface, self-regulation for
charging voltage and current
●Hot-swap MPPT modules for easy maintenance and power expansion
●Auto access MPP tracking states, be most probable to use PV energy in priority
Standard RS232, RS485 and optional SNMP communication port.
Appearance
Product Parameters
Model
10KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
120KVA
Rated power
9 KW
18 KW
27 KW
36 KW
54 KW
72 KW
90 KW
108 KW
Rated current
15A
30A
45A
60A
91A
120A
152A
182A
Output power factor
0.9







Rated input voltage
380 Vac ± 20%







Rated output voltage
380 Vac ± 1%







Battery voltage
360 Vdc







Battery type
Lead-acid battery / Li-ion battery (optional)







Operating mode
AC and PV complementation







PV INPUT








Max. voltage (Voc)
750 Vdc







Optimum operating voltage (Vmp)
450 ~ 550 Vdc







Max. conversion efficiency
not less than 98%







Floating charge voltage (25 )
414 Vdc ± 1%







Equalizing charge voltage (25 )
428 Vdc ± 1%







MPPT Max. current
60 A

120A

180A
240A
300A
360A
Max. PV power
25 KW

2 x25 KW

3x25KW
4x25KW
5x25KW
6x25KW
Number of PV input
1

2 + 1 (reserve)

3 + 1 
4 + 2 
5+3
6+2
MPPT modules
1

2 + 1 (reserve)

3 + 1
4 + 2
5+3
6+2
AC RECTIFIER








Input voltage range
380 Vac ± 20% three-phase







Rated frequency
50 Hz / 60 Hz ± 5 Hz (settable)







Power factor
0.8







Floating charge voltage (25 )
410 Vdc ± 1%







Equalizing charge voltage (25 )
415 Vdc ± 1%







Max. charging current
12A
25A
38A
50A
75A
167A
208A
250A
INVERTER








Inverter voltage
380 Vac three-phase L+ N + PE







Phase voltage
220 / 230 / 240 Vac (settable)







Output voltage precision
±1%







Transient voltage range
±5%







Transient recovery time
20 ms







Rated frequency
50 Hz / 60 Hz ± 1 Hz (settable)







Frequency tracking range
50 Hz / 60 Hz ± 3 Hz







Peak factor
3 : 1







Waveform
Sinusoidal







Waveform distortion
less than 3% (linear load)







Voltage unbalance
±3% (100% unbalanced load)







Overload
more than 105% ~ 110% for 1 h; 110% ~ 125% for 10 mins; 125% ~ 150% for 1 min; 150% shut down in 10 s; 200% shut down immediately







Short circuit
Current-limiting, shut down immediately until the user start up







Max. efficiency
90%
91%
92%

93%



BYPASS








Rated voltage
380 Vac three-phase L+ N + PE







Voltage range
±20%







Rated frequency
50 Hz / 60 Hz ± 5 Hz







Max. current
19A
38A
57A
76A
114A
152A
190A
228A
OTHERS








Protections
Over/under voltage, over/under-frequency, output overload, short-circuit, overtemperature, battery low voltage, overcharge, PV reverse polarity







Communications
RS232 / RS485 / dry contacts (standard), SNMP / Wi-Fi / GPRS (optional)







Display
LCD & LED







Standards
EN 62040-1, EN 62040-2, IEC 62040-2







IP rating
IP 20







Operating temperature
0℃~ 40℃







Relative humidity
90% (non-condensing)







Altitude
1000 m at rated power (derating 1% for each additional 100 m); Max. 4000 m







Dimensions 
450×840×1100mm

600 × 700 × 1750mm


960 ×800 × 1700mm


Packaged dimensions 
560×940×1300mm

700 × 800 × 1950mm


1060 × 900 × 1900mm


Net weight (kg)
210
223
360
410
495
828
834
840
Gross weight (kg)
230
245
380
430
515
848
854
860
AC Mains Wiring
80-120 kVA Inverter Wiring in a Single Mains System
80-120 kVA Inverter Wiring in a Dual Mains System
Three phase solar inverter(UPS)system solution
Our Factory
Fast Contact

Camille hong

Email:camille@lovsunpv.com
Mob/WhatsAPP/Wechat:
+8613170196835
Web:www.lovsun-energy.com
Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links