3 Working Station Laboratory Glove Box with Gas Purification
System
Features
Specifications
Working Voltage | AC 110 - 240 V 50/60 Hz |
Max. Power Consumption | 3KW |
Glove Box Chamber | Dimensions: 3660mm(L) x 750mm(W) x 900mm(H) |
Airlock Chamber | Antechamber Dimensions: 360mm(Dia.) x 600mm(L) |
Two Transparent Front Panels | 1.Front Panel made of transparent plastic 2.Each Panel Dimension: 1170 mm(L) x 700mm(W) 3.Removable for putting in devices |
Attainable purity level | 1.Water concentration: <1 ppm (20°C, 1 atm) 2.Oxygen concentration: <1 ppm (20°C, 1 atm) |
Working Gas | 1.Operating gas: Inert gas such as N2, Ar, He 2.Regenerating gas: Mixture of H2 (5%) and Operating gas |
Gas Purification System | Auto regeneration process |
Filter System | 1.One Organic Solvent Filter System filled with replaceable activated carbon (5.2kg) 2.Two pieces of HEPA filters can eliminate particle size > 0.3μm |
Control system | PLC control system with 6" touchscreen display |
Feedthroughs | Can be 110VAC or 220VAC depending on the input source |
Vacuum pump | Vacuum rate: 4.7 cfm |
Compliance | CE Certified |
Warranty | One years limited warranty with lifetime technical support |
Application Notes & Warnings | 1.The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 2.The use of corrosive gases is prohibited as they will damage the water sensors. 3.Regularly perform regeneration to maintain the optimum purification efficiency. 4.The H2O removing rate is largely dependent on the type of purging gas used. For faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass. 5.Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid vapour may condense and corrode the steel chamber and purification pipeline. |
Working Voltage | AC 110 - 240 V 50/60 Hz |
Max. Power Consumption | 3KW |
Glove Box Chamber | Dimensions: 3660mm(L) x 750mm(W) x 900mm(H) |
Airlock Chamber | Antechamber Dimensions: 360mm(Dia.) x 600mm(L) |
Two Transparent Front Panels | 1.Front Panel made of transparent plastic 2.Each Panel Dimension: 1170 mm(L) x 700mm(W) 3.Removable for putting in devices |
Attainable purity level | 1.Water concentration: <1 ppm (20°C, 1 atm) 2.Oxygen concentration: <1 ppm (20°C, 1 atm) |
Working Gas | 1.Operating gas: Inert gas such as N2, Ar, He 2.Regenerating gas: Mixture of H2 (5%) and Operating gas |
Gas Purification System | Auto regeneration process |
Filter System | 1.One Organic Solvent Filter System filled with replaceable activated carbon (5.2kg) 2.Two pieces of HEPA filters can eliminate particle size > 0.3μm |
Control system | PLC control system with 6" touchscreen display |
Feedthroughs | Can be 110VAC or 220VAC depending on the input source |
Vacuum pump | Vacuum rate: 4.7 cfm |
Compliance | CE Certified |
Warranty | One years limited warranty with lifetime technical support |
Application Notes & Warnings | 1.The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 2.The use of corrosive gases is prohibited as they will damage the water sensors. 3.Regularly perform regeneration to maintain the optimum purification efficiency. 4.The H2O removing rate is largely dependent on the type of purging gas used. For faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass. 5.Corrosive liquid (such as LiPF6 electrolyte) must be remain sealed in a container inside the glove box. Otherwise, liquid vapour may condense and corrode the steel chamber and purification pipeline. |
Specifications of Standard Model of Purification Glove Box | ||||||
No. | Model No. | Box Dimensions | Total Dimensions | Operating Sides | Numbers of Gloves | Options |
1 | GBP800S-2 | 1200*800*930mm | 1915*830*1830mm | Single | 2 | Single or double purification columns |
2 | GBP1000S-4 | 1200*1000*930mm | 1915*1060*1830mm | Single | 4 | Single or double purification columns |
3 | GBP1000D-4 | 1200*1000*930mm | 1915*1060*1830mm | Double | 4 | Single or double purification columns |
4 | GBP1200S-2 | 1200*1200*930mm | 1915*1260*1830mm | Single | 2 | Single or double purification columns |
5 | GBP1200D-4 | 1200*1200*930mm | 1915*1260*1830mm | Double | 4 | Single or double purification columns |
|
|
|
|
|
|
|
6 | GBP800S-3 | 1500*800*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
7 | GBP1000S-3 | 1500*1000*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
8 | GBP1000D-6 | 1500*1000*930mm | 2215*1060*1830mm | Double | 6 | Single or double purification columns |
9 | GBP1200S-3 | 1500*1200*930mm | 2215*1260*1830mm | Single | 3 | Single or double purification columns |
10 | GBP1200D-6 | 1500*1200*930mm | 2215*1260*1830mm | Double | 6 | Single or double purification columns |
|
|
|
|
|
|
|
11 | GBP800S-4 | 1900*800*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
12 | GBP1000S-4 | 1900*1000*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
13 | GBP1000D-8 | 1900*1000*930mm | 2615*1060*1830mm | Double | 8 | Single or double purification columns |
14 | GBP1200S-4 | 1900*1200*930mm | 2615*1260*1830mm | Single | 4 | Single or double purification columns |
15 | GBP1200D-8 | 1900*1200*930mm | 2615*1260*1830mm | Double | 8 | Single or double purification columns |
Notes: |
Product Iamges
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damaged part for you for free.
DELIVERY TIME:15-20 days after confirming the order, detail delivery date should be decided according to production season and order quantity.
1. Which procedure to secure your Quality?
1.Order processing?
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items