  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
welfare
cylinder capacity:
70L
cylinder size:
1500* 267*5.7mm
inside gas:
co2
gas weight:
45kg
storage pressure(20℃):
5.7MPa
max working pressure(50℃):
14.4MPa
cylinder painting:
red coating polyseter RAL3000
Supply Ability
Supply Ability:
100 Set/Sets per Month
Packaging & Delivery
Packaging Details
WOODEN CASE
Port
guangzhou

CO2 fire extinguishing system stored cylinder  

 

 

1.High-press CO2 Fire-extinguishing System Introduction:

 

The carbon dioxide is liquidized by high pressure and stored in cylinders, when spraying the 

carbon dioxide is expending sharply and absorbing a large quantity of heat, thus to reduce

 

the temperature of the fire scene and dilute the oxygen level of the protected zone so as to put 

the fire out. Carbon dioxide is a inert gas, which is inexpensive, non-polluted, dissipated, and 

traceless. The carbon dioxide fire extinguishing system is able to put gas fire out after the gas 

 supply source is cut, and it is also able to put out liquid fire, solid fire of fusible materials such as 

paraffin and asphalt, solid surface fire, deep-seated solid fire such as wincey, fabric, and paper, 

and electric fire, etc. The system is applicable to libraries, archives, database, bulk storages of 

liquid, computer rooms, communication rooms, generator rooms, substation rooms, oil immersion 

slots, mechanical mills, drying devices, and lacquer product lines. Note that carbon dioxide causes 

asphyxiation and the system shall be used where no people are involved. If the system takes 

effect in working places appropriate measures shall be taken to ensure safety.

The system puts out fires in a sealed room in a total flooding mode, it also works in a local 

application mode to put out non deep-seated fire of protected objects where sealed rooms are 

 

not required. The local application mode uses special nozzles which allow the extinguishing agent 

acts fully on combustion object directly, the system keeps supplying extinguishing agent on the 

combustion object for a certain time and intensity in order to put out the fire.

 

 

2.CO2 Gas cylinder technical parameters:

 

Volume:70L;                                                   

Accessories: tank / valve/ internal siphon tube/flexible hose/gas check valve;                                                                                 

Tank size:1500* 267*5.7m(diameter*height*thickness);                                                           

Gas weight:45kg                                                      

Storage pressure(20℃):5.7MPa                                                

Max working pressure(50℃): 14.4MPa                                                    

Painting:  red epoxy polysteter RAL3000/red coating polyster RAL3000;                                                     

Valve size:brass,thread: PZ39, hose thread: G5/8, release pressure:19 ±0.95;

Container valve is consisted of valve body, starter device, piston, relief device, etc.                                                               

Extinguishing agent spraying time:≤60s;                               

Protective area temperature:0℃~50℃                                   

Spraying leavings of cylinder:≤3Kg/bottle

 

MODEL 

70LTR 

WORKING PRESSURE (MPa)

  5.17

DICHARGE TIME (s)

  ≤60

FILLING WEIGHT /BOTTLE 

  42

CAPACITY (LTR)

  70

WORKING TEMPERATURE 

  0~49

NOZZLE WORKING PRESSURE (MPa)

  ≥1.4

LEAKAGE DECTOR 

  10%

 HEIGHT OF PRECTED OF NOZLLE (m)

  0.3—6.5

SYSTEM ACTING MEANS 

AUTOMATICEMERGENCY MANUAL,MACHINICA

EXTINGUISHING WAYSS

 TOTAL FLOODING,PART FLOODING 

SYSTEM WORKING POWER 

  24V,1A 

WORKING RESSURE OF SELF RELEASE PRESSURE (MPa)

  15±0.75

ACTING  PRESSURE OF CYLINDER SAFETY RELASE (MPa)  

  7.0±0.35

 RETARDING TIME OF SYSTEM (s)

  ≤30

 

 

 

3.CO2 Fire suppression system accessories:

 

Fire control panel syotistem, smoke/heat/phc detector system, alarm system(fire bell, manual call,video audio alarm),equipment, cylinder, valve, selective valve, liquid,che,preck pipessure switch, 

nozzle, pipe, ect.

 

 

4.CO2 System order instruction:

You are still in troubling get complex offer?? Hope you meet three following situation

Case 1. If client can supply drawing layout.we can make free design and make offer to you within 24hours, pls send us your drawing room layout.

Case 2. If client has equipment list ?? pls contact us, we can make free design and make offer to you within 24hours

Case 3. No any drawing layout, no equipment list, then give us your room size : length Xwidth X height and door information.

5.CO2 System packing information:

 

Use bubble bag packing the cylinder and accessories,then into wooden case,good protection.

Company Information

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links