9L Stainless Steel Foam type Fire Extinguisher

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 21:08

Other Products
Saddle type water flow indicator
¥Negotiable 11Views

Saddle type water flow indic

Recommend  
Reflective Safety Vest for Dog use
¥Negotiable 8Views

Reflective Safety Vest for D

Recommend  
Top 10 Polyester Fabric Crossfit Wholesale Safety Vest
¥Negotiable 9Views

Top 10 Polyester Fabric Cros

Recommend  
1.3KG 75% SUPER  FIRE BALL EXTINGUISHER AUTOMATIC
¥Negotiable 12Views

1.3KG 75% SUPER FIRE BALL E

Recommend  
emergency eye wash station
¥Negotiable 10Views

emergency eye wash station

Recommend  
You may like
¥Negotiable 40Views

JB2X Junction Box

Recommend  
¥Negotiable 27Views

HB80 china product led solar marine light

Recommend  
¥Negotiable 40Views

DL10D FAA Dual aviation obstruction light

Recommend  
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
Welfare
Cylinder diameter:
D162mm
Cylinder length:
560mm
Cylinder Tmin:
1.2mm
Bottom shape:
Curls base
discharge time:
≥16
discharge range:
≥4
Material:
Stainless Steel
Supply Ability
Supply Ability:
50000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
packed with export carton
Port
Ningbo, China
Product Description

 

Company Information

 

FAQ

 

9L Stainless Steel Foam type Fire Extinguisher

Detail of water fire extinguisher 

9LTR STAINLESS STEEL FIRE EXTINGUISHER
ITEMSPECIFICATION
Capacity9Ltr
Cylinder SizeD162*H560mm
ThreadM30*1.5
Bottom ShapeCurls base
FluorescentGreen fluorescent 37.5
Thickness1.2mm
ValveStainless steel body with hanger loop, middle handle, hose outlet: M16*1.5, 4threads
Gauge

Spring gauge, Diameter 37mm, surface 13.71,  

thread: M10*1-12.5, pressure: 195psi

HoseM16*1.5*630mm
Siphon TubeM16*1.5*500mm
HookSteel hook, with black PVC belt 700mm
Painting ColorStainless steel

 

Parts of 9Ltr Stainless Steel Foam Fire Extinguisher :

Stainless steel valve with hanger loop, middle handle

PVC discharge hose with nozzle

Spring pressure gauge

Steel hook

Plastc belt

Plastic siphon tube

 

 

How to use 9Ltr Foam Fire Extinguisher :

 

First, note that many fire extinguishers will work on a combination of fire classes. 

Quickly decide what type of fire extinguisher you have and ensure that the fire 

extinguisher is compatible with the fire you are attempting to extinguish. ABC dry 

chemical (10LBS/4.5KG) extinguisher is a safe for most fires, especially where 

you"re not sure of the fire origins.

 

1. Break the seal and pull the safety pin from the handle before use the fire 

extinguisher by squeezing the lever, which discharges the fire extinguishing agent.

 

2. Aim the extinguisher nozzle or hose at the base of the fire. It"s vital to stop the fire at its source, or to remove or dampen the fuel from the fire, in order to put it out. By focusing the extinguisher"s spray at the base of the fire or the source, you"re extinguishing the fuel.

 

3. Squeeze the handle or lever slowly to discharge the agent. Letting go of the handle will stop the discharge, so keep it held down.

 

4. Sweep side to side approximately 6 inch over the fire until expended. The sweeping motion helps to extinguish the fire. Stand several feet or metres back from the fire: fire extinguishers are manufactured for use from a distance.

  

Packaging & Shipping

 

Maintenance of 9Ltr Foam Fire Extinguisher :

1. Fire extinguisher is pressure vessel,  should prevent collision during transportation;

2. Extinguisher should placed in dry and ventilated place, temperature range: -10°C~+45°C;

3. Preventing damp, exposure; 

4. Check the parts of extinguisher frequently;

5. Regularly check powder filled, if it is caking,  refilled new and good powder;

6. Regularly check gauge, the pressure is lower or overcharged if its point isn"t in green area, 

    refill according to the position of point;

7. Recharge fire extinguisher immdiately after partial or complete use.

8. Fire extinguisher is supposed to do 2.5Mpa hydraulic test after refilled or used for 5 years, 

    it can be used again after passing the test.

  

Check fire extinguisher frequently to make sure :

 1. Insurance device doesn"t damaged or lost

 2. There is no obvious damage, corrosion, leakage or nozzle blockage phenomenons. 

 3. Gauge reading is supposed to be within working pressure range.

  

Tips & warnings :

1. Inspect 9ltr water fire extinguisher at least once a month. 

2. The needle should be in the green band on the gauge. 

3. Make sure you read your instruction manual carefully. Some fire extinguishers need to be 

    shaken from time to time to prevent the contents from settling. 

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links