Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
China
Long Term
2019-10-17 03:19
Scan By Phone
Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
1.--Addressable smoke detector is a kind of photoelectric smoke detector. With an internal microprocessor.
it supports electronic coding and is accessed through a compatible fire alarm control panel via a two-wire bus.
2.--The detector realizes real-time acquisition of the in situ smoke concentration data
And sends back the data to a fire alarm control panel.
3.--It can also receive and execute the control commands given by a fire alarm control panel.
Addressable Smoke Alarm Detector/Sensor/Alarm | |
Name | Addressable photoelectric smoke detector |
Model | AW-ASD2188 |
External Specification | Diameter 100mm Height 55mm (With Base) |
Weight | 70G |
Matched Host Machine | Addressable Fire Alarm Control Panel AW-AFP2188 |
Installation height | ≤12m |
Pictures showing details of the Smoke Detector
Smoke Detector/Alarms Technical Parameters
1. Executive standard: GB4715-2005
2. Operating voltage: 24V (pulse modulation)
3. Operating current: <300uA (monitoring status) or <1.5mA (alarm status
4. Wiring method: non-polarity two-bus system (L1, L2)
5. Coding mode: It can realize electronic coding via coder in situ. Address codes 1 to 324 are available for selection.
6. Protection area: about 60m2. For details, see related provisions in GB50116-98 Code for Design of Automatic Fire Alarm System
7. Operating environment: Indoor, temperature: -10°C~+55°C;
Relative humidity: ≤95% (40°C±2°C, without condensation)
Work indication: The red indicator will blink in the monitoring status or remain lit in the alarm status.
Smoke Detector Features and Benefits
1.--It can realize electronic coding and rewrite the address via coder in situ.Within a single-chip microcomputer, |
2.--It has a temperature, humidity and dust accumulation drift compensation function and a sensor fault detection function (fault reporting to fire alarm control panel). |
3.--Non-polarity, two-bus connection that ensures convenient installation and maintenance. |
4.--Designed with an upper cover and a lower cover and installed on an independent base, it can be installed, debugged and maintained conveniently. |
addressable smoke alarm,smokle detector,smoke sensors.indoor smoke detector.addressable detector smokes.
photoelectric smoke detector, 2 wire smoke detector, ul approved smoke detectors, conventional smoke detector.
smoke detector fire alarm, smoke detector with control panel
For product pricing, customiztion, or other inquiries
Contact Supplier