Item Descriptions:
Automatic fire extinguisher filling production line
GMT-C CO2 Filler is a small type and portable filler. Both the flask with siphon and
Medial- pressure tank can be used CO2 filling.
Filler must connect with CO2 steel flask while on filling. Meanwhile, the nozzle of the flask must be standard nozzle.
Must use electronic scale as basis of filling weight while on filling.
This GMT-C CO2 Filler does not include electronic scale.
Technical Parameters:
1. Voltage: 220V/50Hz
2. Power: 1.1KW
3. Velocity: 750r/min
4. Pump: three plungers style
5. Filling Volume: Max.-3Kg/min
6. Max. Output Pressure: 140bar
7. Electric Contact Pressure Gauge: pre-set pressure as 120bar
8. Weight: 59Kg
9. Volume: 530×450×420(mm)
Troubleshooting:
Fault | Cause | Solution |
Pump does not generate pressure | 1. The supplying flask not opened. | Open the supplying flask. |
2. The supplying flask does not have siphon. | Replace the supplying flask. |
3. No gas in the supplying flask. | Replace the supplying flask. |
4. Filter blocked. (Figure 2) | Decrease the filler"s pressure to check whether the filler is contaminated. |
5.Pump leaking.(Pump Indicating Figure) | Decrease the filler"s pressure to dismantle the pump body, clean pump parts, and replace the damaged rubber washer. |
Pictures:
Why choose us:
1)we are proffecion in manufacture life saving products
2)OEM available and print your logo
3)we have more than 10 years customer service group and familiar with shipment
which will shipment early & smoothly and reduce the customer cost.
4)Customer service is the first and will be respond within 24 hours.
Customer Reviews total 0 items