Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- ASENWARE
- Model Number:
- AW-AFP2100
- Model:
- 2-Wire Bus Addressable Fire Alarm Control Panel for Project Building
- AC Power:
- 220VAC, 50Hz, 3A
- DC Power:::
- 24VDC, 7.0Ah
- Display Screen:::
- 7.4 Inch LCD back-lit disply
- Crcuit Bus:
- 2-wire bus system
- Connect with PC:
- yes
- Installation:
- Wall- mouned
- Company type:
- fire alarm & suppression as well as relevant detectors manufacturer
- Design:
- OEM/ODM
- Weight:
- 27kg
- Supply Ability:
- 100 Set/Sets per Month
- Packaging Details
- Standard export packing including: 1) Bubble protection 2) Cartons 3) Pallets or plywood case for sea shipping
- Port
- Shenzhen or Hongkong
Shenzhen Asenware Test And Control Technology Co., Ltd, a leading Chinese fire alarm panel & relevant fire detector manufacturer (a technology oriented company), was set up in 2006, the headquarter lies in London of UK. Now it has grown into an international group company in BMS and NDT industries.
The company has two wholly-owned factories: one is in Shenzhen city for BMS products, and the other lies in Dandong city for NDT X-ray products.
A professional and experienced R&D team will offer all-around technical support before, during and after sales, they can also provide professional technical solutions for your items, even arrive in customer’s country to direct projects personally. Our aim is to provide our customers with all-weather and all-around satisfying service.
Profile:
The fire alarm control panel AW-AFP2100 (linkage type) is a new generation intelligent fire alarm and linkage integrated control panel, which is a dual wire analog bus system and can replace the conventional fire alarm control system to save 50% or more cables.
The fire alarm control panel has a modular design and is characterized by great functions, large capacity, flexible configurations and an excellent price-performance ratio.
Each detector, module, manual call point, horn, strobe, hydrant has its own independent address, the fireman or the guard can find the exact fire alarm address instead of a wide area in conventional system.
The fire alarm and linkage control system is extensively applied in high-grade office buildings, big residence communities, department stores, gymnasiums, exhibition halls, libraries,factory buildings, supermarkets, hotels and other large and medium-sized fire protection projects.
Characters:
l 32-bit MCU.
l 2-wire communication between detector/module
l Each detector sensitivity adjustable
l Field-programmable with PS/2 standard PC keyboard and mouse
l 7.4’’ LCD back-lit display
l Windows menu and interface
l Chinese or English interface and panel display
l CF card duplicate or reset system setup file and history file to facilitate maintenance
l Communicate with PC via USB
l Single point start/stop of module(Menu operation)
l Single point test of detector/module
l Zone, building or floor display
l CRT visually display the location of fire and trouble
l Eleven users each with a password and selectable access levels
l Field software upgrade
l Flexible collocation by modularized combination
l Multiple high-speed CAN-bus interfaces, ensuring quick and reliable data
transmission.
Standards that reaches:
GB 4717 - 2005—General Technical Conditions for Fire Alarm Control Units
GB 16806-2006—Automatic Control Systems for Fire Protection
EN 54-2 and EN 54-4—Requirements of European standards
Capacity:
1. Non-polarity two-bus intelligent alarm linkage mode & a total of 324 intelligent detectors or modules for a single circuit.
2. Super high single-machine capacity (maximum single-machine capacity:
40×2×324=25,920 alarm points).
3. Each I/O-board has two loops, with 324 alarm/control points of each loop(Max. control points-324), the capacity of each I/O- board:2*324=648points.
4. Each AW-AFP2100 can connect maximum 3 I/O-boards, the capacity of each AW-AFP2100: 3*648=1944(points). Over 1944 points, the wall-mounted panel turn to cabinet panel, each cabinet panel can connect maximum 40 I/O-boards:40×2×324=25,920 (points).
5. Connected with a multi-line linkage control unit and has a maximum capacity of 4,000 points for a standalone linkage control unit.
Maximum simultaneous alarm of each host:
l Fire alarm:500
l Trouble:500
l Feedback:500
Operating environment:
l Temperature: -10℃~+50℃
l Relative humidity:≤95%
(40℃±2℃, non-condensing)
l AC Power: 220VAC, 50Hz, 3A
l DC Power: 24VDC, 7.0Ah
CBM & KG:
l 0.133m³/pc
l 21.78kg/pc (no battery);
l 26.10kg/pc(including battery)
Parameters of LCD Display Addressable Fire Alarm Control Panel for Big Project :
Name | Addressable Fire Alarm Control Panel |
Model NO | AW-AFP2100 |
Working Environment | In door temperature:-10°C to +55°C |
RH:≤95%(40°C±2°C without condensation) | |
System Capacity: | 648, 1298, 1944 alarm points |
Working voltage: | AC 220V/50Hz |
Bus linkage: | 30 points |
Multi-wire linkage: | 10 points |
Printer: | Standard |
Stand powder: | DC24V/7Ah |
1. Pre-sales: we have R&D center which can offer free technical support and project budget.
2. Sales: 24-hour online prompt reply as well as standard quotation.
3. After-sales:year warranty and technical maintenance.
1. All-round technical support: Yes
2. Warranty: One year
3. Delivery time: Usually about 2 to 5 days.
4. Certificate: CE LPCB ISO9001
5. Payment terms: T/T,L/C,Western union,Money Gram.
Customer Reviews total 0 items