1. 5V50mA Battery Tester is an eight-channel battery analyzer to analyze, voltage 0-5V. Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.
2. This coin cell tester system provides most applications in battery testing fields such as electrode materials research, battery performance test, small scale battery formation, capability grading, battery pack testing, etc.
3. The coin cell tester is suitable for all kinds of coin cell battery such as lithium battery, NI-MH battery, Zn-Mn watch battery and so on.
Specifications
Model |
TMAX-5V50mA |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power8 |
80W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Voltage Range |
0-5V |
Min discharge Voltage |
0V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
0.004A-0.05A |
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
2W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
20ms (0-Full Range) |
Step Time Range |
≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) |
|
Data Recording |
Record Condition |
Minimum Time Interval: 100ms |
Minimum Voltage Interval: 10mV |
||
Minimum Current Interval : 2mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,CPC |
End Conditon |
Voltage,Current,Relative Time,Capacity,-ΔV |
|
Discharge |
Discharge Mode |
CCD,CPD,CRD |
End Condition |
Voltage,Current,Relative Time,Capacity,-ΔV |
|
Pulse |
charge |
CCC |
Discharge |
CCD |
|
Min Pulse Width |
500ms |
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
|
End Condition |
Voltage, Test Time |
|
DCIR |
Support DCIR testing |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
l Power-down Data Protection |
l Off-line Testing Function |
||
l Setting Protection Condition,Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit, Upper Current limit,Delay Time |
||
Hardware Protection |
Additional Anti-reverse Protection Model |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
Database |
MySQL Database |
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
Data Output |
EXCEL,TXT |
|
Communication Interface |
Ethernet Port |
|
Per Unit Main Channels No. |
8 |
|
Dimensions (L*W*H) |
3U,about 500*550*400(mm) |
1 Standard exported package: Internal anticollision protection, external export wooden box packaging.
2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.
3 Responsible for the damage during the shipping process, will change the damage part for you for free.
DELIVERY TIME:15-20 days after confirming order,detail delivery date should be decided according to production season and order quantity.
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items