Built in battery emergency power pack for LED tri-proof light Sanforce LMO102C018T

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Emergency Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 23:38

Other Products
Good quality and cheap in stock rechargeable led emergency led lights lighting
¥Negotiable 11Views

Good quality and cheap in st

Recommend  
Factory direct sales battery pack emergency lighting light battery power
¥Negotiable 10Views

Factory direct sales battery

Recommend  
Reasonble price emergency light led rechargeable battery lights emergency led light
¥Negotiable 20Views

Reasonble price emergency li

Recommend  
Wholesale and retail emergency conversion kit power pack led lights rechargeable exit light
¥Negotiable 10Views

Wholesale and retail emergen

Recommend  
Factory Direct Offer Battery Backup Led Emergency Lighting Inverter Emergency Units
¥Negotiable 14Views

Factory Direct Offer Battery

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Branch:

Array

Size:

5.8X1.8X0.75 cm

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Sanforce
Bulb Type:
LED
Battery Type:
Ni-Cd
Material:
plastic
Usage:
emergency lighting
Certification:
CE
Specifications:
LED LIGHTS
Product Name:
Built in battery emergency power pack for LED tri-proof light
Input Voltage:
220V-240V 50/60HZ
Charge time:
24hrs
Warranty:
3 Years
Emergency Time:
3H
Emergency Power:
6W
Output Voltage:
DC72V
inverter Size:
220*19*11mm
Battery:
Ni-MH
Battery Capacity:
12V/1700mAh

Packaging & Delivery

Selling Units:
Single item
Single package size: 
5.8X1.8X0.75 cm
Single gross weight:
0.5 kg
Package Type:
Inner box size:280*110*57mm Outer box size:350*295*248mm
Picture Example:
package-img
Lead Time:
Quantity(Set)1 - 500501 - 10001001 - 2000>2000
Est. Time(days)101520To be negotiated

 

Model No. LMO103C006T
Product Namerechargeable led emergency power pack for LED light
Battery Type NiMH, NiCd
Lighting Power40W LED tri-proof light
Emergency Power6W
Input voltage     AC85~265V, 50/60Hz
Battery protection     Yes
Operation temperature-20--70℃  , 65+20% RH
Highest Surface Temperature50°C
Battery Capacity7.4V 1100mAh  Rechargeable Li-ion battery
Charging Time>24h without break
Output Voltage in emergencyDC72V
Suitable light sourceLED tube, LED tri-proof tube
Emergency duration180minutes
Product Weight 800g
Inverter dimension220*19*11
NoteCustom-Made battery to be configured with different back-up period and different light output levels. 

 

Description

Emergency conversion kits equipped with slim shape convertor and linear battery pack that is suitable to install into trip-proof LED tube.

Emergency module is invisible and convenient to install on wall, ceiling and any buildings.

 

Features

  • IC controlled Dual rate Charger for energy savings.
  • Short circuit protection at battery terminals.
  • Battery reverse protection functionality
  • Charge indicator and test button. The light fittings guarantee safety of people in buildings open to the general public.
  • Automatically actuated in the event of power cuts, these devices (kit + light fitting) offer a good luminous flux to facilitate the evacuation.
  • Comply with European standards EN 61 347-2-7 and offer a high level of quality and safety meeting the various prevailing regulations.
  • Constant voltage output ,Dial the code to suitable current of luminaires.

 

Sanforce is a manufacturer specializing in emergency conversion kits for LED and fluorescent lighting since 2008.
We cooperate with valuable supply chain, inspect all the incoming materials and set up strict product assurance system, such as SMT, Auto Aging test, Simulation test during our production process. We have very skillful and responsible workers, most of them have been working here over 6 years.
With strong technical support and customer- oriented service, you can be sure that Sanforce is ready to support you, whatever your needs.

 

1.What is your main product line is made?

We are dedicating to LED emergency power pack for commercial lighting, research,
manufacturing and sales, aiming to be a leading emergency lighting backup power producer.
Our main products include:1). Constant current output of Led conversion kit for LED panel
light, LED down lights and other LED light applications with external driver. Emergency
output power differed from 5-90% according to customer’s requirement.
2). 100% emergency output power of emergency kits for LED tube with AC220V or DC110-150V
output.
3). Emergency lighting battery packs for Fluorescent tube 14-98W.
4). High Temperature rechargeable NiCD and NiMH battery pack for emergency control gear
5). Emergency LED T8 tube and min LED T5 3W-4W
6) Constant power emergency kits.

 

 

2.Can inverter be commonly used for any type of light applications?

 

No. It must be confirmed with us case by case

 

3.Can fluorescent emergency kit be used for LED light?

NO
The emergency output is high voltage and high frequency (1000v 230KZ))for fluorescent, That
is not applicable for LED system.

 

4.What is the difference between high temperature battery and normal temperature battery?

The main difference is that high temperature battery can be trickle charged well even
though the emergency power kit stay at high temperature due to insufficient radiating
caused by the lights working for long time, while normal temperature battery may stop
charging in such conditions that result in emergency light failed to work. We would highly
recommend to use high temperature battery for emergency lighting kit.

 

5.Does battery have an end-of-charge detection/over voltage protection?

No, The battery is being charged all the time, The charging current will be decreased based
on the capacity status during the charging process. For NiCD and NiMH battery, it is
applicable for constantly charging without any risk even though no over voltage
protection. But under voltage protection is set up for discharging.

 

6.How long (months/years) before the battery discharge time goes below 2 hours?

Normally 2 years later.For Nicd battery, the capacity will be reduced by 10% at first of
year and 20%of the second year, it will remain 70%-80% after total 3 years.


7.If the battery reaches full charge, (NiCd in our case), and the fitting is supplied with
220VAC all the time, can you explain how does it not damage the battery when it keeps
charging all the time?

For Nicd battery we offered you, we set up the charging current at 0.05C(1/20 battery
capacity) that is suitable for long time constant charging, no any damage for battery. It’
s characteristics of NiCD itself.

 

8.What are your market reach throughout the region?

Our markets mainly spread over Europe, South of America, Africa and Asian Pacific region as
well as domestic marketing, we have 8 years of experience in foreign trade, we have worked
with buyers of lighting importers and distributors etc.

 

 

9.Can the light work as emergency function immediately once we installed the emergency conversion kit into standard lighting applications?

 

NO
The emergency output is high voltage and high frequency (1000v 230KZ))for fluorescent, That
is not applicable for LED system.


10.Your factory or trading company?

We are a factory, we provide OEM services and accept small order. We only focus on the
manufacturing of products-Emergency Conversion Kits.

 


11.You have the ability to do independent research and development?

Our engineering department has 3-5 people, we have the research and development
capabilities. We also collect each customer’s feedback regularly, We have the ability on
product improvement and new product development.

 


12.Why is the fluorescent tube blackened once activate with emergency kit?

The reason is that our emergency output is one way of high frequency pulse,the output of
pulse waveform is not completed but only half of that .But itwill not affect the
functionality of fluorescent tube because of the emergencyrunning is not frequent. Unless
emergency back up functionality is neededall the time that will impact the life of tube
slightly.

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links