Model | MS-35-5 | MSF-35-12 | MS-35-15 | MS-35-24 |
Specification |
DC output voltage | 5V | 12V | 15V | 24V |
DC output current | 0-6A | 0-3A | 0-2.4A | 0-1.5A |
Wave and noise | 60mVp-p | 80mVp-p | 100mVp-p | 100mVp-p |
Inlet stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
Load stablity | ±1% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 77% | 81% | 83% | 84% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
AC input voltage range | 85~264VAC 120~370VDC 47~63Hz |
AC Impact current | Cold-start current 30A/230V |
Overload proctection | 105%-150% cut off the output, automatic recovery |
Over-voltage protection | 115%~135 shut down O/P voltage, re-power on to recover |
Setup rise hold up time | 300ms, 50ms, 80ms/230VAC at full load |
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC |
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ |
Working temperature and humidity | -10°C~+50°C(Refer to output derating curve),20%~90%RH |
Overall dimension | 84*58*38mm |
Weight | 0.22Kgs |
Note: |
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. |
2.Error.include the setting error,line stability and load stability.(Note:5). |
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. |
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. |
5.Load stability test:the load is from 0% to 100%. |
6.C2,3,6must be knocked down. |