Conventional fire alarm beam infrared smoke detector with LPCB

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 23:19

Other Products
CB Listed Twin LED Spot Emergency Lighting
¥Negotiable 12Views

CB Listed Twin LED Spot Emer

Recommend  
Asenware Factory Cost Conventional Emergency Light System Twin Lamp LED Emergency Light AW-EL207 for Shopping Center
¥Negotiable 9Views

Asenware Factory Cost Conven

Recommend  
Ceiling Mounted Dual LED Emergency Lighting System
¥Negotiable 15Views

Ceiling Mounted Dual LED Eme

Recommend  
Long Lasting Automatic  LED Twin Lamp Emergency Light Fire Indicator System
¥Negotiable 10Views

Long Lasting Automatic LED

Recommend  
Non Maintained Running Man Emergency Escape Lighted Light rechargeable Acrylic Pane Led Exit Sign
¥Negotiable 8Views

Non Maintained Running Man E

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-BK901
Alarm type:
Conventional beam infrared smoke detector
Light path Length:
8m~100m
Operating Voltage:
DC16V~DC32V
Adjusting Angle:
-6 DEG ~+6 DEG
Alarm current:
22mA
Housing Materials:
ABS, White shell
Operating Environment:
temperature -10°C~+50°C
External Dimensions:
206mm*95mm*95 mm
Supply Ability
Supply Ability:
5000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Infrared Beam Smoke Detector: PP Bag per Set to protect/Carton Box outside
Port
shenzhen

    Conventional   fire alarm beam smoke detector

 

Product Description

 

Brief introduction

 

AW-BK801 Line Beam Smoke Fire Detector (hereinafter referred to as detector) is a
long-interval reflection line infrared beam smoke detector which must be used together with a
reflector. In case of smoke on the light path of the detector, the signal arriving at the receiver
is reduced; when the light reduction rate reaches the preset threshold, the detector will produce
the alarm signal; when the light beam is completely blocked, the detector will produce the fault
signal to prevent the false alarm caused by non-fire blockage. Thanks to the built-in uniprocessor
with excellent performance, the detector has a powerful analysis and judgment capability and can
automatically complete the systematic debug, the compensation for external environmental
parameter variation, and the judgment of fire alarm and fault, and also can give status indication
through the indicator lamp and the signal output terminal. The detector adopting a brand-new and
reasonable structural design is sensitive in adjustment, correct in positioning, easy in
installation, and simple and convenient in debugging method. The detector contains a group of
alarm passive normally open contacts and a group of fault alarm normally closed contacts as well
as 4-20mA standard signal output to be conveniently connected with the fire alarm system and
DCS system of plants of fire fighting equipment.

 

Characters:
1.Wide operating voltage range and wide protective area
2. Self-diagnosis capability, monitoring of faults in the detector
3. Field setup of two levels of sensitivity
4. Built-in microprocessor, intelligentized fire alarm and fault judgment
5. Fire alarm and fault passive output contacts and standard 4-20mA standard power supply
output
6. Smart design of the detection light path, high antijamming performance, seal protocol,
corrosion protection and waterproof performance
7. Integration of the transmitting part and the receiving part, simple and convenient
installation, good light path collimation
8. Automatic compensation function, and automatic compensation for factors of received signal
reduction such as dust pollution, position deflection, ageing of the transmitting tube, etc. to
some extent
9. Automatic calibration function to enable a single person to complete debug within a short
time, simple operation, easy integration of the transmitting part and the receiving part, simple
and convenient installation, good light path collimation

 

 Picture of the infrared beam smoke detector

 

 

 

Technical Parameters

 

Operating Voltage

 DC16V~DC32V

Adjusting Angle

-6 DEG ~+6 DEG

External Dimensions

206mm×95mm×95 mm (length×width×thickness)

 Material and Color of the Casing

ABS, white

Weight

450g

Light path Length

8m~100m

Operating Current

monitoring current ≤12 mA,

alarm current ≤22mA,

debugging current ≤20mA

Indication of status of the detector

1) Debugging Status: the green, red and yellow indicator lamps light up or flash in a specific mode.

2)  Normal monitoring status: the green indicator lamp flashesperiodically.

3) Fire Alarm: the red indicator lamp keeps lighting;the yellowindicator lamp blacks out. The fire alarm should be cancelled through being powered again.

4) Fault: the yellow indicator lamp keeps lighting; in case of fault recovery, the fault signal of the detector is automatically cancelled by the detector.

5) If the light path is completely blocked, the detector reports a fault and the yellow indicator lamp lights up.

Operating Environment

temperature -10°C~+50°C relative humidity ≤95% withoutcondensation

Protective Area

the maximal protective area of the detector 14×100=1400 m2

 

 

Company Information

 

Asenware, is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005

Our fire safety products, solutions and services are used in over 100 countries.

With over 200 employees work in United Kingdom-Marketing center, China-R&D and Supply Chain center and Bangladesh-Manufacture center, Asenware is committed to design and manufacturer the best fire safety products to reduce the risk of fire, and support the world to be more safe and more comfortable.

 

Product range

 

Addressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system

 

 

 

 

Certificates

 

 

 

 

Our Services

 

1) OEM & ODM service: YES
2) Technical support and After-sale service: YES
3) Warranty: 1 YEAR
4) Delivery Time: 3 - 5 days after payment received
5) Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order

 

 

Contact

 

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links