Conventional Fire Alarm Control Panel for Commercial Building
AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.
Mains supply voltage | 110VAC or 220VAC |
Internal power supply | 27.2VDC |
Total output current limited | 3A @ 220VAC |
Batteries (default configuration) | 12V2.3AH*2 |
Number of circuit | 12-32 |
End of Line device | 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold) |
Call point resistor value | 470 to 680 Ω, 0.5 or 1 watt |
Number of general circuits | 2 |
Outputs fused AT | 600mA |
Maximum number of bells @ 50mA of each Sounder output | 30 |
Battery fuse | 1.85A resettable fuse |
Sounder outputs | 750mA resettable fuse |
Output type | NC and NO relay |
Maximum current | 100mA |
Largest acceptable conductor size | 2.5mm2 |
Smallest acceptable conductor size | 0.75mm2 |
Dimensions(mm) | 640X390X150 |
Weight (with batteries) | 13kg |
Standard safety export package / carton (Box + Foam) or as customized
# OEM/ODM can be provided
# Technical Support like install operates. Any questions will be answered within 24 hours.
# We have professional technical team to help customers solve technical problems.
# Hotel project Hospital factory fire alarm system project can be made
Operating since 2005
Asenware was established in 2005. We have been focusing on fire alarms and BMS (building management systems) for over 11 years. Our headquarter is in London, UK, with factory Shenzhen, China
Supported by Experienced Engineer Team
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Meeting ISO Standard
Based on our ISO 9001 quality control system and our experiences in BMS and NDT, we integrate a series of products in our E-Shop, they are cost-effective and guaranteed quality.
Q1:Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q2:What is the lead time?
A:Sample needs 1-3 days, mass product according to your quantity.
Q3:How do you ship the goods and how long does it take arrive?
A:We usually ship by DHL,UPS,FedEX or by Air. 3-5 days after payment received.
Q4:Do you guarantee for the products?
A:Yes,we offer one year guarantee for the products.
Q5:Do you offer OEM service?
A:Yes,we can design the products according to your request.
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items