Conventional Fire Alarm System/GSM Fire Alarm System/Fire Suppression System

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 03:21

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 9Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 16Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 15Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 12Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 19Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
ASENWARE
Model Number:
AW-AFP2166
Item:
conventional fire alarm system
Mode:
Conventional
Color:
red or as customized
Power supply:
90V AC -270V AC, 50/60Hz
Output voltage:
28V DC +/- 2V
Installation:
Wall hanging
Working Environment:
Construction buildings,factory/hotel/resturant secutiry
Certificates:
CE/ISO9001
Usage:
fire protection
Design:
OEM/ODM
Supply Ability
Supply Ability:
10000 Set/Sets per Quarter
Packaging & Delivery
Packaging Details
Foam bag with export box then into carton
Port
shenzhen

 

 

Key words: Fire alarm Control Panel,conventional fire alarm control panel,  fire alarm panel, fire alarm, FACP, fire alarm system, fire-fighting, fire panel, fire alarm controller, fire alarm control unit

 

Product Description

Conventional Fire Alarm System,GSM Fire Alarm System,Fire Suppression System  

 

Fire Alarm System Overview

 

The automatic extinguisher control panel is designed in accordance with European standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices.

 

The control equipment is a combined fire alarm control panel and extinguish ing system and has three detection zones, any or all of which are capable of contributing to the extinguishant release decision.

 

Control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of EN54-4.

 

Fire Alarm System Parameters

 

   Temperature-10°C~+50°C
Humidity  ≤95%
Power supply  AC 220V 50HZ DC 24V 6A
Output contact capacity  AC 220V 1A DC 27.6V 3A
 

DC power

 

DC24V 5.0Ah, two fully sealed maintenance-free DC12V 5.0Ah storage batteries connected in series

 

AC input voltage

 

AC 220V±20%  50Hz

 

AW-AFP2188 system capacity

 

100/200/324 points (non-polarity, two wire bus, fully mixed coding)

 

Fire Alarm System Specification

 

 

ITEM

1Zone panel

2Zone panel

4-8 Zone panel

12-32 Zone panel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-8

AW-CFP2166-12-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @ 240VAC

500mA @ 240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-16

4-32

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Line fault monitor for detector removal

Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor

End of Line device

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Detector continuity diodes

Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)

Call point resistor value

470 to 680 Ω, 0.225 or 0.5 watt

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

Fuses

 

Battery fuse

1.5A F 20mm

Sounder outputs

500mA F 20mm

Fire and fault output

 

 

Detailed Images

 

 

 

Fire Alarm System Show

 

 

fire alarm system

  

  

 

  

 

 

 

Accessories

 Fire Alarm System Accessries

 

 

ItemModel
Conventional Smoke DetectorAW-CSD311
Strobe SounderAW-CSS2166-2
Fire Alarm BellAW-CBL2166-B
Manual call point AW-CMC2166-5
Break Glass Manual call pointAW-CMC2166-1 
Flash lightAW-CBL2166

 

 Fire Alarm System Circuit Diagram

 

 

 

 

Company Information

 

Shenzhen Asenware Test And Control Technology Co., Ltd was set up in 2006, our headquarters is in London of UK. Now Asenware is an international group company in BMS and NDT industries.
We are a technology oriented company that devotes to NDT(Non Destructive Test) and BMS(Building Management System) industries.
We have two factories : one factory is in Shenzhen city for BMS products, and the another is in Dandong city for NDT X-ray products.
In our BMS factory, we produce addressable and conventional fire alarm system, CCTV camera and DDC controller.
In our NDT X-ray factory, we produce portable and mobile NDT X-ray flaw detectors, X-ray analysis equipment and the dark room accessories.
We have an experienced R&D team to design special electric product for test and control usage.
We have been striving to provide customers with satifying service before, during and after sales.

 

 

 

Our Services

 

1.Pre-sales:we have R&D center which can offer free technical support and project budget.

 

2.Sales:24 hour on line prompt reply,norm quotation

 

3.After-sales:1 year warranty,technical maintance

 

 

 

Packaging & Shipping

Fire Alarm System Packaging and Shipping

 

 

 

 

 

 

 FM200 Automatic Fire Extinguisher Control Panel/Fire Extinguishing System

5 to 30 VDC 1A Amp maximum for each

fm200 fire system,fire extinguish system,fire alarming system, fm200 fire suppression system, fm 200 fire suppression system, fm

FAQ

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links