Conventional fire protection system panel for kitchen

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 02:52

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 9Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 16Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 15Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 12Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 19Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
China
Brand Name:
Asenware
Model Number:
AW-GEC2169
Product name:
Fire Suppression Contol Panel
Model:
AW-GEC2169
Usage:
Fire Fighting
AC input:
220VAC 50Hz
Voltage for MCU:
5V for power board MCU, 3.3V for other MCU
Batteries:
Two 12V/ 2.3AH maintenance-free lead-acid batteries series connection
Temperature range:
-5 to 40°C (23~104°F)
Humidity:
5 to 95% RH, non-condensing
Dimension:
(L)350*(W)280*(T)112.5mm
Packing size:
(L)375*(W)305*(H)130mm
Supply Ability
Supply Ability:
1000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
By carton
Port
ZHONGSHAN PORT
Picture Example:
package-img
Lead Time:
Quantity(Pieces)1 - 1000 >1000
Est. Time(days)20To be negotiated
Product Description

Overview

AW-GEC2169 extinguishing control panel is designed in compliance with the requirements of European standards of EN54-2, EN54-4 and EN12094-1. This panel can be used in FM200, CO2, IG541, Novec1230 and other gas fire extinguishing systems.

Executed clause of standards

1.EN54-2 Fire detection and fire alarm systemspart 2: control and indicating equipment
2.EN54-4 Fire detection and fire alarm systemspart 4: power supply equipment
3.EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices

Parameters
AC input:
220VAC 50Hz
DC output from power board:
24VDC (19V-28V) and 5VDC (4.9V-5.1V)
Voltage for MCU:
5V for power board MCU, 3.3V for other MCU
Current at 24VDC from PSE:
<450mA standby current
Maximum current from PSE:
1.4A (except batteries charge current)
Batteries discharge current:
1.85A maximum, current-limited
Auxiliary power output:
24VDC, 200 mA max, current limited
Batteries:
Two 12V/ 2.3AH maintenance-free lead-acid batteries series connection
Zone alarm current:
6-27mA
Detector numbers in each zone:
16 pcs
 Alarm terminal maximum output current:
200mA maximum
Temperature range: 
-5 to 40°C (23~104°F)
Humidity: 
5 to 95% RH, non-condensing
The wire between interface board (Panel) and detector (recommended):
2-core shielded cable for 12 to18 AWG
(0.75 to 2.5 mm2)
Panel dimension: 
(L)350*(W)280*(T)112.5mm

Installation

1. The panel shall be mounted on a dry, flat wall, maintained at sight height to ensure external chassis balance. The panel should be fixed by 3 pcs of M6mm screws properly.

2. The panel should not be installed in a sealed environment or near an over heat source. Suitable insulated cables should be used in the corresponding position. If additional cable entry points are required, all chips and debris generated by drilling must be removed before the panel is energized.

3. Preparation: ensure that the installation site is free of construction dust, debris, extreme temperature ranges and humidity.

4. The ground wire shall connect to the AC power supply. We recommend using 16AWG (1.3mm2) wire to wiring.

5.Make sure the AC circuit breaker is disconnect before wiring from the AC circuit (220-240 VAC) to the power terminal.

Packing & Delivery
Company Information

About us

ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.
Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and gas suppression system.

Factory

Exhibition


Thailand Exhibition


Philippine Exhibition

Certifications
Our Service

* Over 10 years" experience.
* Prompt response.
* OEM & ODM is available.
* Support factory inspection.
* Standard quality control system.
* Different choices of payment and delivery.

* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.

Related Products

AW-FP300

Addressable fire alarm panel FP300


AW-FP100

Addressable fire alarm panel FP100

AW-CFP2166

Conventional fire alarm panel 2166

Contact us

Please feel free to contact me for more details!
Contact: Rella Liang
Whatsapp/wechat/Tel: 0086 13670150613
Email: sales15 "@" asenware.com  

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links