Model | DR-30-5 | DR-30-12 | DR-30-15 | DR-30-24 |
| DC voltage | 5V | 12V | 15V | 24V |
output | Current range | 0~3A | 0~2A | 0~2A | 0~1.5A |
| Rated power | 15W | 24W | 30W | 36W |
| Ripple&noise | 80mvp-p | 120mvp-p | 12mvp-p | 120mvp-p |
| DCvoltage ADJ.range | ±10% | ±10% | ±10% | ±10% |
| Voltage range | 85~264VAC,120~370VDC 47-63Hz |
| Efficiency | 74% | 81% | 82% | 83% |
| Inrush current | Cold start current 15A/115VAC,30A/230VAC |
| Over load | 105%~150% cut off the output,automatic recovery |
| Over voltage | 115%-135% shut down O/P voltage, re-power on to recover |
environment | Working temperature | -10°C~+50°C |
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute |
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
others | Dimension | 78*93*56mm (L*W*H) |
Weight/packing | 0.27kg/45pcs/13kg/43*32*21.5cm |
note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |
Customer Reviews total 0 items