  Electronic ballast for uvc lamp

 

 

1. Brief Introduction

LPCU-1PH-A-3 is a high frequency electronic ballast, with high performance. It starts and drives middle pressure gas discharge lamp, which has dimming control system as well. How do it works shows at below:

 

2.Working conditions

Environment temperature:-5℃~+5

Relative humidity :≤95%  

Altitude≤1500M

Meet IEC61373-2010 standard requirement

 

3.Electric parameters

 

LPCU-1PH-A-3

Lamp power(max)

(Output power)

3kW

Lamp voltage

(Output voltage)

300V-500V (depend on the lamp)

output current

<8.6A

Input voltage

206-278VAC,single phase

Input current

17A(Max)typical valve

Input frequency

46-63Hz

Power factor

0.98(Typical value) 

Efficiency

>94%(Typical value)

Harmonic current distortion

<5%(Typical value)

Range of output power

15%-100%

Output frequency

40-200kHz

Ignition voltage

1650Vp

Protect function

Output short circuit protection,Open load protection,Output over voltage protection,Input over voltage protection,Input undervoltage protection,high temperature protection

Lamp monitor

Current Monitor,voltage monitor

Control way

IO(Compatible with PLC),

CAN open,

RS485(MODBUS)

Working environment temperature

-5℃~+55

High humidity

90%

Cooling way

Forced air cooling,water-cooling

Protection class

IP20

Size

329*135*65

Weight

4kg

 

 

4. Electrical interface

 

1.Input port

 

 

 

Connector:PC 5/ 3-STF1-7,62 – 1777846

 

 2.Output port

 

  

 

Connector:PC 5/ 3-STF1-7,62 – 1777846 

 

3.Control port A

 

   

 

Connector:Phoenix MC 0,5/8-G-2,5

Connected with PLC IO,Read 5-control way

 

4.Control port B

 

  

 

Connector:Phoenix MC 0,5/7-G-2,5

CAN BUS, RS422/RS485 Communication interface. Read 5-control way

 

5.Control way

This Model ballast has three control ways of PLC I0 Hard wire, CAN Bus communication, RS485/RS422 BUS Communication, chosen by code switch.

 

   

 

As code switch shows above, it stands for number 17.

     

Number meaning on Code switch 

 

Code switch value

Control way

0

 hard wire control

Non O

CAN bus/RS422 bus communication control

Code switch value is the communication address

 

 

  1.Hard wire control

 Control port A connected with IO of the PLC,using the PLC to control the ballast.

 

  1.1 pin definition 

 

Pin 

Function

Direction

Type

Description

1

PLC COM (0V)

Input

0V

the cathode of external power

2

Must Dangling

 

 

 

3

Fault code 1

Output

Open connector

 

Low level means fault(driver fault)

4

Fault code 2

Output

Open connector

Low level means fault(system fault)

5

Fault code 3

 

Output

Open connector

Low level means fault(indicator light fault)

6

START/STOP

Input

24V

The anode of external power

7

Lamp light on signal

Output

Open connector

Low level means lamp works

8

Dimming control

Input

PWM

Duty ratio controls power

 

  1.2 Controller PLC connecting wire grid 

 

  1.3 lighting

 

1.3.1 Control port A Pin 6 connect with 24V, ballast starts output.

1.3.2 lights on all, control port A Pin 7, output low level

 

 

  1.4 Dimming control

 

Exterior PWM signal enters into Ballast, ballast starts dimming control. PWM signal frequency scale: (1KHZ-3KHZ)

 

PWM Duty ratio

Lamp Power

<10%

450W

10%

450W

97%

3000W

100%

3000W

 

  2.CAN bus control way

Read “LPCU-1PH-A-3 CAN OPEN”protocol

 

  3.RS422/RS485 bus control way

Read “LPCU-1PH-A-3 MODBUS”protocol

 

6. LED lamp indication

The ballast has five led indicator lights. 

 

Name

Description

RUN

Supply power, “RUN” Lights on, ballast operates.

LAMP

Indicator light flashes, lamp is on the process of lighting on.

Indicator light on stably, lamp finishes starting.

Indicator light off, lamp off.

FAULT

Indicator light on, fault happens. (Ballast default or lamp default)

TX

Indicator light flashes, communication data is sending. (CAN BUS OR RS485 BUS)

Indicator light doesn’t flash, no data is sending.

RX

Indicator light flashes, communication data is accepting. (CAN BUS OR RS485 BUS)

Indicator light doesn’t flash, no data is accepting.

 

7.Dawing of overall dimensions

 