EN54 Standard fire control equipment! 8 zone conventional fire alarm control panel

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 03:20

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 9Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 16Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 15Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 12Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 19Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware Fire Alarm Manufactor
Model Number:
AW-CFP2166-8
Mode:
AW-CFP2166-8
Circuits/zones:
8
Voltage:
110VAC or 240VAC
Internal power supply:
27.2VDC
Main supply monitor for fault:
Yes
Installation:
Wall hanging
Certificates:
CE.ISO9001
Design principle:
Based on EN54 part 2&4 standard
Company type:
Fire control equipment
Produce:
Addressable and conventional fire alarm system
Supply Ability
Supply Ability:
3000 Unit/Units per Month 10-years fire alarm manufactor
Packaging & Delivery
Packaging Details
PP Bag per Set to protect/Carton Box outside
Port
Shenzhen or Hongkong

1.The conventional fire alarm system control panel general description:

-- The AW-CFP2166 is atranditional type of fire alarm control paneldesigned based on EN54 part 2&4 standard.

--It is steady and widely used to work with other brands fire alarm detectors/sensors like manual call point/break glass, smoke detector, heat detector, combined smoke and heat detector, strobe with sounder, flash light, fire bell, etc.

-- It is modularized design, the panel can extend from 1 zone to 32 zones easily.

 

2.Details of the conventional fire alarm control system control panel :

1) The outlook of the conventional fire alarm control panel:

 

 

2).The characteristics of the conventional  fire alarm control system control panels:

 

Model

AW-CFP2166 , 1 to 32 zones

Design principle

The series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

control mode

2 level control mode by a lock

power supply output

27VDC

signal output

Has FIRE PROTECTION, FIRE ROUTING and FAULT signal output; the output can be configured to dry relay type or wet sources type.

sounders output

Has 2 channel general sounders output.

Special function

  1. Each zone has 1 circuit detectors input .
  2. Each zone can be disable by a button.
  3. It has RESET button to reset the panel.
  4. It has SILENCE button to stop BUZZER and SOUNDERS.
  5. It has EVACUATE button to start a manual fire alarm immediately.
  6. It has TEST button to test all LEDs orderly.
  7. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
  8. It has an optional GSM module for fire alarm by SMS .

Service Environment

industrial and civil buildings

factories, hospitals, restaurants, hotels, schools, business buildings, government buildings,etc.

Advantage

Efficient feedback, steady and easy to work with other brands fire products,Humanization setting, Economic, User friendly,etc.

 

 

3. Main technical parameters of AW-CFP2166 conventional fire alarm control panel:

 

ITEM

1 Zone panel

2 Zone panel

4-8 Zone panel

4-32 Zonepanel

Model No.

AW-CFP2166-01

AW-CFP2166-02

AW-CFP2166-04-16

AW-CFP2166-04-32

Power specification

 

Mains supply voltage

110VAC or 240VAC

Internal power supply

27.2VDC

Total output current limited

500mA @ 240VAC

500mA @ 240VAC

3A @ 240VAC

3A @ 240VAC

Main supply monitor for fault

Yes

Battery protection for low voltage

Yes

Batteries (default configuration)

12V2AH*2

Detector circuit specification

 

Number of circuit

1

2

4-16

4-32

Maximum number of smoke/heat detectors per zone

20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.

Maximum number of manual call points per zone

No limit

Sounder circuit specification

 

Number of general circuits

2

End of line resistor value

6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)

Line fault monitor for open circuit

Yes

Line fault monitor for short circuit

Yes

Outputs fused AT

400mA

Maximum number of bells @ 20mA of each sounder output

20

Fuses

 

27VDC fuse

3A F 20mm

Fire and fault output

 

Output type

Dry relay output :NC and NO relay; wet source output

Maximum current

100mA

Size and weight

 

 

Dimensions(mm)

272*200*70mm

320*231*90mm

395X502X124

362X565X124

Weight (without batteries)

4kg

5kg

7kg

8kg

Weight (with batteries)

5.8kg

6.8kg

9.6kg

12.5kg

 

 

4. System diagram of the conventional fire alarm panel

 

5.The Whole Fire Alarm Control Panel System

 

The conventional fire alarm control system 2166 series matchedthe below detectors and accessories:

 

1) AW-CSD311:conventional photoelectric smoke detector

 

2) AW-CTD805: conventional fixed temperature heat detector

 

3) AW-CSH202:conventional smoke and heat combind detector

 

4) AW-CMC2166-1, AW-CMC2166-5: conventional manual call point/break glass

 

5) AW-CSS2166-2: conventional hooter/horn

 

6) AW-CBL2166-A: conventional fire bell

 

7) AW-CBL2166: conventional flash light

 

 

 

Company Information

 

 

 

 

 

 

 

Certificates

 

 

 

 

Our Services

Ø OEM & ODM service: YES

Ø Technical support and After-sale service: YES

Ø Warranty: 1 YEAR

Ø Delivery Time: 3 - 5 days after payment received

Ø Shipping: delivery by air, ship or DHL, FEDX etc. Express for your order

 

 

Name Card

 

                          Reliable 8zone  conventional fire alarm control panel    EN54 Standard fire control equipment

security fire alarm system , gsm fire alarm system,fire alarm control systems,gsm fire alarm system,fire alarm,fire alarm control panel,fire alarm panel,fire alarm system,fire control panel,fire control,fire alarm control unit,fire control equipment,fire control panel, fire detection control panel, gas control panel, conventio nal fire panel, addressable fire alarm panel, addressable fire panels, fire protection panel

 

 

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links