EVEN EMI-LT T8 LED Tube Emergency Light Conversion Kit For LED Tube 1-3 hours Customized

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2020-12-23 20:14

Other Products
EVEN EMI-LT T8 LED Tube Emergency Light Conversion Kit For LED Tube 1-3 hours Customized
¥Negotiable 59Views

EVEN EMI-LT T8 LED Tube Emer

Recommend  
You may like
¥Negotiable 37Views

SL-DM-100 High quality Solar LED flood remote light

Recommend  
¥Negotiable 41Views

ST400 high quality High lumen high bay light 400w

Recommend  
¥Negotiable 36Views

TY4W Solar Powered High Intensity Obstruction Light

Recommend  
¥Negotiable 37Views

Wholesale SMD IP65 150W high bay light

Recommend  
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Product Description

EVEN EMI-LT T8 LED Tube Emergency Light Conversion Kit For LED Tube 1-3 hours Customized                                                   

  

 

 

Model  No.EME-EL
Product NameEVEN EMI-LT T8 LED Tube Emergency Light Conversion Kit For LED Tube 1-3 hours Customized
Battery TypeNi-CD/Ni-MH/18650 Li-ion Battery
Lighting PowerLED Light With external/Internal Driver
Emergency Power10-50W
Input voltage     AC85~265V, 50/60Hz
Battery protection     Yes
Operation temperature-20--70℃  , 65+20% RH
Highest Surface Temperature50°C
Battery Capacity3*3000mAh  Rechargeable battery pack
Charging Time>24h without break
Emergency OutputCustom
Suitable light sourceSuit for indoor light/outdoor light
Emergency power10-100%
Emergency duration1-3hours
Inverter dimension155*40*30mm
Outer casing size360*105*45mm (Custom)
NoteCustom battery pack according to different backup time and and the brightness when emergency

 

 


  

Related Products

 

 

 

 

 

OEM Service

 

Shenzhen EVEN Technology Co., Ltd is the leading battery manufacturer in China, who focus on emergency Lighting Kit,LiFePO4, Li-polymer, Li-ion, NI-MH, and NI-CD rechargeable batteries, our products passed by UL, CE, ROHS and FCC certifications.
 
Our company has 8 years experienced in R&D about battery in mainland and 4 years export to overseas.In our ISO 9001:2008-certified factories, which span a total of 16,000 m2, we can turn out over 3,000,000Ah monthly production capacity. With professional R&D team, experienced workers and advanced equipments, we are determined to provide you high-quality battery.

EVEN has development,manufacture,selling and service department as a whole.
We own our complete production techniques and superior testing device.What we make emergency pack has its practicability and easy to install.Our IC control circuit board use from import,which make sure that use more security,higher efficiency,more energy conservation and environment protection,longer life and other more advantages.So it is popular to selling in Europe,United Kingdom,Chile,Hongkong,Asia and others countries and regions.The emergency pack from EVEN both use normal commercial power and emergency power,it will be quick and automatic when it switches.
 
Our batteries are widely used in electronic products which include handheld device, medical equipment, GPS, electric bicycle , emergency lighting, duplicate reading battery machine , miner's lamp, two-ways radio , outside advertising board, UPS, solar energy system, auto starting system ect.

We take humanistic management as our concept, regarding people as the most important factor in our development.We pay attention to safety & environmental protection and take the responsibility of the society. With great passion and faithfulness, we are willing to provide our customers perfect service and striding forward with you to create a bright future.

Functions

 

Finished Products

 For example low voltage emergency pack as following for your reference(more other type,pls contact EVEN :

 

3.Product details :

LED Strip : 24W

Output Voltage :DC12V

Output Current : 2A

 

4.Emergency Solution:

1. According to EN60598; EN 55015; CE;

2. Deep discharge protection

3. Operation time (discharge):1hour(Customized within 1hr)

4.Lumen Factor : 50%

5.Emergency Output:DC12V/1A

6.Matched Emergency Solution : 6V/2.5Ah Ni-CD Battery + Inverter+ Metal Box+ Inner Box

 

5. Dimension (mm ):

  Battery Size : C type (50*25mm/cell)

  Inverter Size : 155*40*30mm

 

6.Application:

Product name: Emergency module for LED Strip

 

7.Specifications of Drawing, Schedule and Symbols:

 

L = “live”wire

N= “Neutral” wire sometimes called “nil” or “0”

Switch = a mechanical device that connects or interrupts a “life”wire to the driver.

LED Driver is an electronic device that drives the LED lighting fixture with a constant current.

SL is switched Life wire connection on the LED driver

N is the Neutral connection on the LED driver

+ on the LED driver is the positive connection from driver to the LED fixture

- on the LED driver is the negative connection from driver to the LED fixture

5.Usage range :

 

1Hotels

2Conference/Meeting rooms

3Factories & Offices

4Commercial Purposes

5Residential/Institution Buildings

6Schools, Colleges & Universities

7Hospitals

8Places where energy saving and high color rendering index lightings are required

 

 

 

9.Installation Instruction:

 

-Connection 1 is used for safety ground (earth)

-Connection 2 is used for connecting to the life wire of the buildings electricity network before the

switch, sensing if the life wire is “alife”

-Connection 3 is used for connecting the neutral of the buildings electricity network

-Connection 4, 5 and 6 are not used. Or connect “L” of building electricity to connection 4(SL),

and connect Driver “L”,”N”with connection 5 and 6.

-Connection 7 and 8 have a test switch

-Connection 9 (positive +) and 10 (negative -) for connecting a control LED meaning Life

electricity is connected and “alive”.

-Connection 11 (positive +) and 12 (negative -) are used to connect the battery for emergency

operation.

-Connection 13 (positive +) and 14 (negative -) are used to connect the LED system driver.

-Connection 15 (positive +) and 16 (negative -) are used to connect the LED fixture to the current driver of the module.

 

10.Operation

The module is capable of testing the performance of the emergency luminaire in accordance with

IEC EN61347-2-7 & EN61347-2-13.

 

11.Commissioning Test

Connection of the mains supply will initiate commissioning where the battery will remain on charge for an uninterrupted 24 hours. An interruption of the mains supply will impact the accuracy of emergency running duration.

 

12.Functional test

This test can be initiated manually by pressing the Testing Button.

 

13.Duration Test

A full rated duration test is carried out after charge the battery for 24 hours.

Note that start times of the tests are set based on the battery capacity.

 

14.Charge LED Indicator

A range of LEDs are available in red or green, diffused or clear high intensity, with or without a fitted rubber bezel or plastic clip and with various lead lengths.Check the LED charge indicator is on with the mains present and battery is being charged while inverter is working well.

 

Attentions:

 

-          Pay extra attention to the negative and the positive pole of the battery in order to prevent

reverse operation, please use designated and matching batteries and ensure all wiring is done

correctly and stable before use.

-  If you need to do product testing, unplug the battery pack when the emergency device is

disconnected from the mains supply, and then plug in the battery after the emergency device is

completely shut down.

-           Comply with the wiring connection circuit diagram completely, prevent from over loading and

non loading in the process of use and testing.

-          In order to prolong the battery powered lighting time, all indicator lights are switched off

during normal use with the emergency power system in standby mode.

-           The battery is not charged before leaving the factory; please charge the battery longer than 24

hours before use.

-          In general, the battery needs to be fully charged and discharged for around 3- 5 times in order

for the Ni-CD/Ni-MH battery to operate at full capacity.

8-  It is detrimental for the Ni-CD/Ni-MH battery to lie idle for a long time, especially when it runs

dead. Charge the battery completely when it is out of operation for a long time. (The battery cannot

lie idle for more than three months)

 

Important:

 

It is recommended that the module is installed by a competent person ensuring the installation complies with the necessary standards. EVEN accepts no responsibility for injury, damage or loss, which may arise as a result of incorrect installation, operation or maintenance. the conversion requires an unswitched supply for charging the battery and a switched supply for a maintained conversion.Ensure that the finished converted luminaire operates within the module and battery temperature ratings.Ensure that the original luminaire components are still operating within their temperature ratings.

 

Note the production date of the battery.

-Charge the battery completely when it is out of operation over 3 month.

-Check the emergency module functionality for 3 month intervals.

-Replace the battery every 3 years interval

 

Company Information

 
Why Choosing Us


LED lighting plays a key important role in daily life,accordingly,the emergency kit is also important within this products.

Emergency Lighting Inverters need professional understanding of battery specification to get good performance. We develop our inverters inch by inch to best fit lights and battery.

Therefore, rather than its price, the reliability is the top factor to consider.

More experiences we have,more professional will service for you.

You are most welcome to contact us by Skype, e-mail, telephone call or even walk in to talk to us. We will try best to get best solution for you.

 

Catalogues

 

 

Our Services

 OEM/ODM for wholesales and retailers who need emergency project.

 

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links