AW-GEC2169 extinguishing control panel is designed in compliance with the requirements of European standards of EN54-2, EN54-4 and EN12094-1. This panel can be used in FM200, CO2, IG541, Novec1230 and other gas fire extinguishing systems.
1.EN54-2 Fire detection and fire alarm systemspart 2: control and indicating equipment
2.EN54-4 Fire detection and fire alarm systemspart 4: power supply equipment
3.EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices
Parameters | |||
AC input: | 220VAC 50Hz | ||
DC output from power board: | 24VDC (19V-28V) and 5VDC (4.9V-5.1V) | ||
Voltage for MCU: | 5V for power board MCU, 3.3V for other MCU | ||
Current at 24VDC from PSE: | <450mA standby current | ||
Maximum current from PSE: | 1.4A (except batteries charge current) | ||
Batteries discharge current: | 1.85A maximum, current-limited | ||
Auxiliary power output: | 24VDC, 200 mA max, current limited | ||
Batteries: | Two 12V/ 2.3AH maintenance-free lead-acid batteries series connection | ||
Zone alarm current: | 6-27mA | ||
Detector numbers in each zone: | 16 pcs | ||
Alarm terminal maximum output current: | 200mA maximum | ||
Temperature range: | -5 to 40°C (23~104°F) | ||
Humidity: | 5 to 95% RH, non-condensing | ||
The wire between interface board (Panel) and detector (recommended): | 2-core shielded cable for 12 to18 AWG (0.75 to 2.5 mm2) | ||
Panel dimension: | (L)350*(W)280*(T)112.5mm |
1. The panel shall be mounted on a dry, flat wall, maintained at sight height to ensure external chassis balance. The panel should be fixed by 3 pcs of M6mm screws properly.
2. The panel should not be installed in a sealed environment or near an over heat source. Suitable insulated cables should be used in the corresponding position. If additional cable entry points are required, all chips and debris generated by drilling must be removed before the panel is energized.
3. Preparation: ensure that the installation site is free of construction dust, debris, extreme temperature ranges and humidity.
4. The ground wire shall connect to the AC power supply. We recommend using 16AWG (1.3mm2) wire to wiring.
5.Make sure the AC circuit breaker is disconnect before wiring from the AC circuit (220-240 VAC) to the power terminal.
ASENWARE is the fire alarm system and fire suppression system manufacturer and whole fire safety solution provider since 2005.
Driven by a commitment to sound operations, ongoing innovation, and open collaboration, we have established a competitive fire safety products line include addressable fire alarm system, conventional fire alarm system, central monitoring emergency light system, fire telephone and gas suppression system.
Thailand Exhibition
Philippine Exhibition
* Over 10 years" experience.
* Prompt response.
* OEM & ODM is available.
* Support factory inspection.
* Standard quality control system.
* Different choices of payment and delivery.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.
Conventional fire alarm panel 2166
Please feel free to contact me for more details!