Factory price 220V AC advanced 4/8/16 zones fire alarm control panel
Factory price 220V AC advanced fire alarm control panel
Product Description
Fire alarm control panel:
SR-P01-4 4 zones conventional fire alarm control panel
SR-P01-8 8 zones conventional fire alarm control panel
SR-P01-1616 zones conventional fire alarm control panel
The SR-P01 Series Conventional Fire Alarm Control Panel is 220VAC, 50 Hz, four to sixteen-zone(Selected by the customer), Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective SR-P01 Series can be used in a variety of low- to mid-sized applications.
Main features:
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept two-wire smoke detectors and any normally-open contact devices. Two Supervisory Input with DC12V output, ideal to connect security alarm devices. Three General Alarm, Trouble and Supervisory, Form A Relay Output. One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits (NACs), NACs may be programmed: Silenceable or Non-Silenceable. 3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output. Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode. RS485 Communication Port (optional). Automatic/Manual mode can be programmed. Disable/Enable control per Zone (IDC) can be programmed. Disable/Enable Sound Output(NACs) can be programmed.
Technical Parameters
AC Power
220VAC, 50 Hz.
Battery
Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge
Maximum battery charger capacity
18AH battery
NOTE
Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box
Total DC24V system power
3.0 amps
Maximum current per NAC
1.25 amps
Maximum battery charging capability
18 AH
Resettable four-wire smoke detector power output.
yes
Non-resettable power output.
yes
Integral Form-A Alarm, Trouble and Supervisory relays, rated at
This fire alarm control panel can Match any 2/4-wire smoke heat detector,strobe siren,fire bell,manual call point ect
smoke detector
2 wire, 4 wire optiona, photoeletrci type
heat detector
2 wire, 4 wire optional, rate of rise or fixed temeparture
strobe siren
wired type, with or without strobe
fire bell
wired type, indoor or outdoor type
manual call point
resettable type or breaking glass type optional
Not only the alarm control panel we have, but also we offer all kinds of detectors you want, we are looking forward to your inquiry, thank you!
Company Information
Our Services
Payment terms:L/C,D/A,D/P,T/T, Western Union,Paypal ect Delivery time :Normal order within 7 days,bulk order 10-15 days Packing:Neutral paper box and paper carton
Customer Reviews total 0 items