Fire alarm 220v smoke detector parameters
Operating Voltage Range | 9 to 28 VDC Volts Non-polarized |
Standby Current | ≤60μA@24VDC |
Maximum Alarm Current (LED on) | ≤30mA@24VDC (1K Ohm current-limiting resistance) |
Operating Humidity Range | ≤95%RH(40°C±2°C) Relative Humidity, Non-condensing |
Operating Temperature Range | -10°C to 50°C (14°F to 122°F) |
Smoke Alarm Sensitivity | 0.15-0.3dB/m |
Temperature Alarm Sensitivity | 57°C (135°F) A1R (only for with heat sensor) |
Conventional 220V fire alarm smoke detector description
The Conventional fire alarm 220v smoke detector AW-CSD311 are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire
alarm panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every six
seconds indicating that power is applied and the detector is working properly. The LEDs latch on
in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is
outside the listed limit. The alarm can be reset only by a momentary power interruption.
The detector that initiated the alarm condition will have its red LED and relays latched until reset
by panel.
The whole conventional fire alarm system detailed show
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.
Packaging : Analog Smoke Detector: PP Bag per Set to protect/Carton Box outside .
Shpping :UPS FEDEX EMS DHL TNT
1.OEM ODM can be provided .
2.Technical support like how to install operate .Any question will be answer within 24 hours .
3.We have prfessional technical team to help customers solve technical problems .
4.Hotel project hospital factory fire alarm system project can be made .
Shenzhen Asenware Test And Control Technology Co., Ltd was set up in 2006, our headquarters is in London of UK. Now Asenware is an international group company in BMS and NDT industries.
We are a technology oriented company that devotes to NDT(Non Destructive Test) and BMS(Building Management System) industries.
We have two factories : one factory is in Shenzhen city for BMS products, and the another is in Dandong city for NDT X-ray products.
In our BMS factory, we produce addressable and conventional fire alarm system, CCTV camera and DDC controller.
We have an experienced R&D team to design special electric product for test and control usage.
We have been striving to provide customers with satifying service before, during and after sales.
Payment terms :T/T L/C Western union .
Delievry time :usually about 2 to 5 days .Mass product about three weeks .
Warranty :one year
Certificate :CE LPCB ISO9001
Technical support :yes