Fire Fighting System 2 Zone Conventional Control Panel

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-11-19 18:28

Other Products
Infrared beam motion smoke detector indoor and high quality infrared beam smoke alarm
¥Negotiable 28Views

Infrared beam motion smoke d

Recommend  
TUV Approved  LED Emergency light led light rechargeable lead-acid
¥Negotiable 31Views

TUV Approved LED Emergency

Recommend  
Factory price Remote control Twin Head LED Emergency Light
¥Negotiable 26Views

Factory price Remote control

Recommend  
Asenware 24V DC addressable fire alarm input module
¥Negotiable 23Views

Asenware 24V DC addressable

Recommend  
high sensitive addressable model price for heat sensor
¥Negotiable 23Views

high sensitive addressable m

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-GEC2169
Material:
Metal
Product name:
FM200 fire suppression system gas release control panel
Color:
Red Color
Zone number:
2 zone
Capacity:
16Detectors One Zone
Alarm function:
High Decibel Alram Sound
Usage:
Automatic release Gas
Size:
280*112.5*350mm
Warranty:
1 year
Function:
FM200 gas release control panel
Supply Ability
Supply Ability:
10000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Carton box
Port
Zhognshan
Lead Time:
Quantity(Pieces)1 - 1011 - 5051 - 100 >100
Est. Time(days)71520To be negotiated
Product Description

The AW-GEC2169 automatic gas fire extinguisher panel has the following features:


The AW-GEC2169 automatic gas fire extinguisher panel has the following features:
1.Stand-by power build-in:with build-in two battery when AC power off.
2.Delay time resettable: delay time resetable between 0-60s when release the gas.
3.Power Switching (between AC and Stand by Battery)
4.Anti-Misoperation: Press Abort to Stop the extinguishant to be released under mis-operation.
5.GSM Module Optional Installation

Upgrade feature

1.Durable: outside metal cabinet with visiable glass window of opening and closing door .
2.Resetable: panel reboot time and extinguishant release both can be delayed.  
3.Multifunctional: Resetable 24VDC port can connect 4 wire devices
4.selectable : Enable/Disable function
5.Pre-alarm : Pre-alarm is the first stage fire alarm.
6.Standard: excuted standard of EN54-2, EN12094-1


Specification
AC INPUT
220VAC 50Hz
DC OUTPUT at Power Board
24VDC (19V-28V) and 5VDC (4.9V-5.1V)
Voltage for MCU
5V for power board MCU, 3.3V for others
Current at 24VDC from PSE
<450mA standby current
Maximu current from PSE
1.4A except batteries charge
Batteries current
1.85A maximum, current limited
Auxiliary output
24VDC, 200 mA max, current limited
Extinguishant release delay time
Adjustable 0 to 60seconds(5 second steps)
Imin, Imax.a and Imax.b according to EN54-2
Imin=340mA, Imax.a=424mA, Imax.b=1.4A
Batteries
2*12V/ 2.3Ah sealed lead acid gel, self-regulated
Battery replace Resistance
1.6Ω±10% if needed
Battery low-voltage protection
21V
The maximum and minimum electrical ratings for each input and output
Detectots / zone lines: 15.2V-28V Sounder lines:19-28V
Fire protection/Fire routing lines:19-28V Fault routing lines:
18-28V
Detectors wiring allowed each zone
16 devices
Zone alarm current
6mA minimum/ 27mA maximum
Communication protocol
2 wires RS485 bus system
Environmental
Class A temperature range: -5 to 40°C (23~104°F)
Humidity
5 to 95% RH, non-condensing
Wires between interface board (Panel)and Detector
2-core shielded cable for 12 to18 AWG
Related producs

1. Addressable fire alarm system(FP100 series,LPCB FP300 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet

Shipping & packaging

Packaging Details:


1) PEE bag per unit
2) Outside Cartons
3)Strict & Standard Export Packing Procedures Adopted Exterior Corrugated Hardboard Carton Interior Blister Buffer Staff, Asenware fire pump control equipment.

Our Service

1.OEM / ODM services.
2.Professional technical team.
3.Offer Free technical support whenever you need
4.Two year warranty and technical maintenance


FAQ:

Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: 
Fire control: one week working day. bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days

Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.

Our Company

Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.

Contact us

EMAIL.

sales09(@)asenware.com.

Skype.

sales09_155

TEL.(Whatsapp/Wechat).

008613590128969

Certification
Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links