Goodwe On Off Grid Hybrid Inverter GW5048D ES Series Single Phase Hybrid Inverter

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Batteries
  • Validity Period:

    Long Term

  • Published on:

    2021-12-28 11:20

Other Products
On grid tie solar inverter growatt 50kW 60kw 70kw 80kw MPPT inverters for solar panel energy system power plant
¥Negotiable 117Views

On grid tie solar inverter g

Recommend  
3 Years Warranty Lead Carbon 12V 2V 100Ah 200Ah 400Ah 600Ah VRLA Gel Lead Acid Battery
¥Negotiable 68Views

3 Years Warranty Lead Carbon

Recommend  
Lovsun VRLA Solar GEL Battery 2V 200AH 400 ah Opzv With Factory Price
¥Negotiable 106Views

Lovsun VRLA Solar GEL Batter

Recommend  
Deep Cycle OPZV Lead-acid Solar Gel Battery 2V 1000ah 1500ah 2000ah Solar Battery
¥Negotiable 99Views

Deep Cycle OPZV Lead-acid So

Recommend  
Tier 1 Trina Vertex 490w 500w 510w Solar Panel 485w 495w 505w Half Cut Cells Monocrystalline PV Module
¥Negotiable 56Views

Tier 1 Trina Vertex 490w 500

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Product Description
The GoodWe ES series bi-directional hybrid energy storage inverter is suitable for on-grid PV systems. It can also control the flow of energy intelligently. During the day, the PV plant generates electricity which can be provided to the loads, fed into the grid or charge the battery. The electricity stored can be released when the loads require it during the night. Additionally, the power grid can also charge the storage devices via the inverter.
Product Parameters
Datasheet
GW3648D-ES
GW5048D-ES
Battery Input Data
Battery Type
Li-Ion
Nominal Battery Voltage (V)
48
Max. Charging Voltage (V)
≤60 (Configurable)
Max. Charging Current (A)*1
75
100
Max. Discharging Current (A)*1
75
100
Battery Capacity (Ah)*2
50~2000
Charging Strategy for Li-Ion Battery
Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W)
4600
6500
Max. DC Input Voltage (V)
580
MPPT Range (V)
125~550
Start-up Voltage (V)
125
Min. Feed-in Voltage (V)*3
150
MPPT Range for Full Load (V)
170~500
215~500
Nominal DC Input Voltage (V)
360
Max. Input Current (A)
11/11
Max. Short Current (A)
13.8/13.8
No. of MPP Trackers
2
No. of Strings per MPP Tracker
1
AC Output Data(On-grid)
Nominal Apparent Power Output to Utility Grid (VA)*8
3680
4600
Max. Apparent Power Output to Utility Grid (VA))*4*9
3680
5100
Max. Apparent Power from Utility Grid (VA)
7360
9200
Nominal Output Voltage (V)
230
Nominal Ouput Freqency (Hz)
50/60
Max. AC Current Output to Utility Grid (A)
16
24.5*5
Max. AC Current From Utility Grid (A)
32
40
Output Power Factor
~1(Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output)
<3%
AC Output Data(On-grid)
Max. Output Apparent Power (VA)
3680
4600
Peak Output Apparent Power (VA)*6
5520,10sec
6900,10sec
Max. Ouput Current (A)
16
20
Nominal Output Voltage (V)
230 (±2%)
Nominal Ouput Frequency (Hz)
50/60 (±0.2%)
Output THDv (@Linear Load)
<3%
Efficiency
Max. Efficiency
97.60%
Max. Battery to Load Efficiency
94.00%
European Efficiency
97.00%
Protection
Anti-Islanding Protection
Integrated
PV String Input Reverse Polarity Protection
Integrated
Insulation Resistor Detection
Integrated
Residual Current Monitoring Unit
Integrated
Output Over Current Protection
Integrated
Output Short Protection
Integrated
Output Over Voltage Protection
Integrated
General Data
Operating Temperature Range (°C)
-25~60
Relative Humidity
0~95%
Operating Altitude (m)
≤4000
Cooling
Natural Convection
Noise (dB)
<25
User Interface
LED & APP
Communication with BMS*7
RS485; CAN
Communication with Meter
RS485
Communicaiton with Portal
Wi-Fi
Weight (kg)
28
30
Size (Width*Height*Depth mm)
516*440*184
Mounting
Wall Bracket
Protection Degree
IP65
Standby Self Consumption (W)
<13
Topology
Battery Isolation
*1 : The actual charge and discharge current also depends on the battery.
*2 : Under off-grid mode, then battery capacity should be more than 100Ah.
*3 : When there is no battery connected, inverter starts feeding in only if string voltage is higher than 200V.
*4 : 4600 for VDE 0126-1-1 &VDE-AR-N4105, 4950 for AS4777.2(GW5048D-ES), 4050 for CEI 0-21 (GW3648D-ES).
*5 : 21.7A for AS4777.2.
*6 : Can be reached only if PV and battery power are enough.
*7 : CAN communication is configured by default. If 485 communication is used, please
replace the corresponding communication line.
*8 : For Belgium Nominal Apparent Power Output to Utility Grid (VA): GW3648D-ES is 3600.
*9 : For Belgium Max. Output Apparent Power (VA): GW3648D-ES is 3600.
Projects
Packing&Shipping
Delivery & Payment Terms





Payment Terms


T/T
EXW
30%T/T in advance,paid the balance before shipment
FOB
CFR(C&F)
30%T/T in advance,paid the balance against copy of B/L
CIF
L/C
Optional L/C amount above 50,000usd, we can accept L/C at sight
West Union

Optional for amount less than 5000usd
paypal
Delivery Time
7~10days after receiving payment for one container
Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links