Southeast Asia 40.00%
North America 25.00%
South America 25.00%
Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Our company specializes in manufacturing 30 years of production and development of various types of elevators dedicated cross-flow fan, the lift fan motor, instrument cooling fan, cooling fan drive, dry type transformer cooling fan, fan purification equipment, heating and cooling fan and other equipment with a fan. Production GUANGYA (Guangya brand) brand fan and motor, the current domestic production of fan motors, fans and lift fan, from raw materials to finished products are the Company's internal manufacturing, also in the only one-stop professional production enterprises, the company detected well-equipped, strong product design and development capabilities, strict management services, products through the China quality certification Center "CCC" certification (certificate of 2009010702358554), CE, ROHS, ISO-9001 certification.
Instructions for use:
1, this series has been optimized fan design, painstakingly created, with luxury, security, through the national patent and CCC certification.
2, the product is suitable for the family room, shopping malls, the elevator car, control rooms, laboratories, plant health workshop, aisle corridor
And other places as well as air conditioning equipment for hair ventilation ventilation.
Installation Notes:
1. Check that the fan nameplate voltage and frequency, 110V or 220V.
2. There will be two kinds of location means the fan embedded and ceiling.
Embedded: The installation will remove the ceiling, light steel frame confirm specifications are divided into 2 feet x2 feet & 595mm x595mm
Ceiling: Install the fan according to flattened above a predetermined size drill 4 fixing screws
3. Position the fan in the desired position and, indeed, after the installation of light steel frame embedded in a flat roof, the fan power supply terminal (terminal pillar) combined with external power supply quick connector terminals.
4. Check the fan starts rotating for unusual or abnormal sound generation, to prevent damage during transport phenomena, the normal operation of the fan to complete the installation.
5. Install the fan in the house means there is some room off the power switch without fuse of 20A to be used, turn off the power off the unit takes off the power.
Instructions:
1. Before proceeding, make sure all cables are connected properly, there is no short circuit or wrong connection.
2. The fan remote control, based on electronic touch switch and timer replace the traditional mechanical switches and timers: IR remote control distance of up to 10 meters on the remote control angle.
3. When To activate, press the fan button "Weak Strong" is the fan-start, yellow LED lights up, shutdown, press the "off" button. Every time you press a second "Weak Strong" button, it will sequentially → weak, medium, strong ... circular, cycle selection
(Initial power silent weak wind) weak wind → yellow LED lights green LED lights stroke → Strong Wind → red LED lights
4. Press the fan button lighting, 1. 2. warm white light color temperature of white light 3 lights. Each time the button to cycle.
5. Press the button to turn the fan page, each page turn buttons left and right direction.
6. Press the fan timer button, the timer starts the fan, the red LED indicator lights, timed 2 hours, the blue LED is lit, the timing for 4 hours
Red and blue LED lights, timed six hours, when the regular time to time, the fan will automatically stop all work. Each time you press each key, the fan inside the buzzer will "drop" is called a Function.
Maintenance and cleaning step instructions:
1. To keep fans clean and beautiful, the fan should be regularly cleaned.
2. Make sure the power is disconnected, the body will be moved to the ground flat.
3. Wind wheel clamp knob loose reverse unloading, you can remove the turntable.
4. The panel cover eight screws in addition to feeding the panel cover removed.
5. The rear fan blade has a first fixing screw is removed, the blades were cleaned
6. Remove the blade wheel, rinse with water
7. The parts of the motor housing and do not rinse, wipe with a dry cloth can easily remove dust
8. After cleaning, dry all parts, according to the above-described step eleven to replace parts
Technical Parameters:
Stalls | First Stalls | Second Stalls | Third Stalls |
Rotating Speed | 750 to 850 | 850 to 950 | 1100 to 1200 |
Air Flow | 11m3 / min | 18m3 / min | 25m3 / min |
Noise | 40DB | 50DB | 58DB |
Precautions
1. Before installing the fan confirm working voltage is normal.
2. Connect the power cord columnar pin terminal portion to be determined immediately.
3. The fan mounting height from the ground is greater than 2.3m above the light steel armor on a flat roof, when the fan rotation ,Please don't let the finger or stick, etc., and other inserted in order to avoid injuries, especially please take care of the children.
4. The fan should not be higher than the ambient temperature above 40 ℃ places is prohibited in conductive dust, explosive,
too much oil, too wet, corrosive environment places washout use.
5. Non-professionals may not disassemble repair the product, to avoid accidents, the fan during operation, such as hair
Students have smoke smelling odors and other phenomena, should immediately cut off the power supply and inform the maintenance professionals
Service
This product within 12 months, the product due to manufacturing quality problems and damage occurred from the date of shipment or not working properly
For when the factory repair or replacement free of charge for users.
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items