First, the use of HB72 products: Counter, meter, timer, time controller, frequency meter for (Mai Chongji), tachometer / speed meter. Two, HB72 product features HB72 by setting the product function number, can realize the time delay, tired, frequency, speed, count a total of 32 functions HB72 - six relay working mode, fully meet the needs of field control The HB72 pulse signal, switch, mechanical contact signal input compatible The HB72 can be connected with a proximity switch, photoelectric switch, rotary encoder, sensor HB72 - set value, current value, a current count value is retained HB72 product delivery: HB72 generally spot
Three, HB72 characteristic index HB72 display: four double display - HB72 trigger mode: NPN, PNP can be set HB72 contact capacity: AC220V/3A; DC24V/5A - HB72 operating temperature: 0-50 degrees HB72 power supply: AC/DC24 - 260V - HB72 relative humidity: 20-85%RH Frequency response: 10KHz - HB72 - HB72 stock temperature: -10 to 70 DEG C HB72 contact life: 100 thousand dimensions: 72*72*112mm - HB72 HB72 digital size: 0.56 inch HB72 - hole size: 67*67mm Three. HB72 relay working mode 1 HB72 power meter, reaches or exceeds the set value relay 2 HB72 power meter doesn"t work (by reset or reset terminal makes the instrument work), meet or exceed the set value of relay 3 HB72 power meter work to achieve or exceed the set value when the relay is released 4 HB72 power meter does not work (can be reset or reset the terminal to make the instrument work), to reach or exceed the set value of the relay release 5 HB72 power meter, reaches or exceeds the set value to reset relay, time setting, automatic instrument reset, start work again 6 HB72 power meter doesn"t work (by reset or reset terminal makes the instrument work), meet or exceed the set value to reset relay, time setting, automatic instrument reset, start work again
Four, HB72 product function number, description, scope of work Function number function 01 single delay time (positive) 0.01S - 99.99S 02 single delay (inverted) 0.01S - 99.99S 03 single delay time (positive) 1M - 9999M 04 single delay (inverted) 1M - 9999M 05 single delay (positive) 1S - 9999S 06 single delay (inverted) 1S - 9999S 07 single delay time (positive) 1S - 99M59S 08 single delay (inverted) 1S - 99M59S 09 single delay time (positive) 1M - 99H59M 10 single delay (inverted) 1M - 99H59M 11 double delay (positive) 1M - 99H59M 12 double delay (inverted) 1M - 99H59M 13 double delay (positive) 1S - 99M59S 14 double delay (inverted) 1S - 99M59S 15 double delay (positive) 1S - 9999S 16 double delay (inverted) 1S - 9999S 17 double delay (positive) 1M - 9999M 18 double delay (inverted) 1M - 9999M The 19 hour (immediately reset) 0 - 99H59M59.99S The 20 hour (8 seconds reset) 0 - 99H59M59.99S The 21 hour (immediately reset) 0 - 9999H59M59S The 22 hour (8 seconds reset) 0 - 9999H59M59S The 23 hour (immediately reset) 0 - 9999D23H59M The 24 hour (8 seconds reset) 0 - 9999D23H59M 25 frequency 1HZ----9999HZ 26 frequency 1.0HZ----999.9HZ 27 rpm 60----9999RPM 28 frequency / speed (general) 1 - 9999 29 reversible counting 1 - 9999 30 reversible counting 1 - 9999 31 reversible counting 0 - 99999999 32 reversible counting 0 - 99999999
Customer Reviews total 0 items