HFC-227ea fire fighting system with full accessories

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 21:08

Other Products
Saddle type water flow indicator
¥Negotiable 11Views

Saddle type water flow indic

Recommend  
Reflective Safety Vest for Dog use
¥Negotiable 8Views

Reflective Safety Vest for D

Recommend  
Top 10 Polyester Fabric Crossfit Wholesale Safety Vest
¥Negotiable 9Views

Top 10 Polyester Fabric Cros

Recommend  
1.3KG 75% SUPER  FIRE BALL EXTINGUISHER AUTOMATIC
¥Negotiable 12Views

1.3KG 75% SUPER FIRE BALL E

Recommend  
emergency eye wash station
¥Negotiable 10Views

emergency eye wash station

Recommend  
You may like
¥Negotiable 39Views

mecree led flood light 400w

Recommend  
¥Negotiable 47Views

GK500 LED Flood Light

Recommend  
¥Negotiable 27Views

HB80 china product led solar marine light

Recommend  
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
WELFARE
Model Number:
HFC-227ea
Capacity:
20ltr to 343ltr
working pressure:
25 bar, 42bar, 56bar
max discarge:
less 10S
working temperature:
-10 to +50C
Valve:
brass
Acuated:
manual , automatic , and eletrical
Supply Ability
Supply Ability:
100 Set/Sets per Month
Packaging & Delivery
Packaging Details
wooden case
Port
ningbo
Lead Time:
Quantity(Sets)1 - 50 >50
Est. Time(days)10To be negotiated

1.HFC-227ea fire fighting system breif introduction:

 

1.Design According to following Standard:

CHINA GB795. GB79G , GB410, GB14104 , NFPA-2001(U.S.A)

GA400-2002  "Testing Way and Performance of extinguishing system Parts "

Inside Gas : EX6288 describled NFPA2001

2.HFC-227ea is a clean extinguishing agent, which would completely vaporized in the air,

and well insulated. Its total flooding mode is applicable to electric fire, liquid fire or fusible solid fire,solid surface fire, gas fire which gas supply is cut before extinguishing. And it is 

able to protect computer rooms, communication rooms, substation rooms, hi-tech device rooms, 

generator rooms, gasoline storerooms, combustible chemical storerooms, libraries, data rooms, 

archives, treasuries, etc. We manufacture HFC-227ea system that is well structured, reliable, 

and widely applied to computer rooms, archives, program control exchange engine rooms, 

TV broadcast center, financial organizations and government departments.

 

2.HFC-227EA system main technical parameters:

 

1. Storage of cylinder: 20L~450L

2. Storage Pressure: 2.5MPa/4.2MPa(20)

3. Maximum Working Pressure (50): 3.4MPa/5.3MPa

4. Operating Method: electromagnetic starter; emergency mechanical starter

5. Nitrogen pressure of the electromagnetic driving device: 6.0±1.0MPa (20)

6. Starter power of the electromagnetic driving device:  DC24V/1.5A

7. Extinguishing agent filling density: ≤950kg/m3

8. Extinguishing agent spurting time: ≤8s

9. Protective Area Temperature: 0~50

10. Cylinder spurting allowance: ≤2kg/bottle

11. Cylinder-room temperature requirement: -10~50

 

 

3.HFC-227EA fire extinguishing system all parts see below:

All accessories made of this system: cylinder, valve, gauge, electrical actuator, flexible hose, liquid one way valve, manifold pipe, pressure switch, safety valve, cylinder racket, pilot cylinder +valve, gas check pipe, low leakage high sealing valve, no return valve etc..

 

 

 

4.HFC-227EA fire extinguishing system packing picture:

 

 Use wooden case to packing,protect cylinder to avoid impact.

5.HFC-227EA fire extinguishing system order instruction:

 

HFC-227ea Fire Suppression system is one of Special Design and Manufacture products .

Before we make offer, we need your detailed information support to calculate the qty of Cylinder, weight of gas ,pipe size, nozzle ...

if the system you requested need design or not ?we design them free charges ,

We need following information to make design for your engineer projected

1>,What’s your protected subject :

Telecommunication Facilities________Computer operations _______Control rooms __________

Shipboard (marine )system ________Rare book Libraries _________University and Museum? 

Art Galleries _________________Petrochemical installations _________Medical Facilities and Pharmaceutical________ 

2>,do you have room "s layout or drawing

yes ( if yes please send us your attachment ) 

2. no (if no please tell us below protection status)

A room size : length(X width(m)X height ( m) (M)

B raise floor(can not greater than 30mm): _______(M ), or NO _____

C ceiling , height ____ (M) , or .no need consider

3> do you need a pressure release device ,yes .

4> storage cylinder must be placed in a separate room and towards the door opening direction

5> HFC-227ea system select

A. Dependable system one system protect a single room(no need flow check valve)

B. Muliti-hazard system (One system protect multiple rooms(use selection valve)_________

6>.do you need fire alarm products ( control panel ,detectors , gas lamp ) yes no

7>.do you need pipe net yes no

8 >.do you need coupling and pipes yes . no

9>.do you need nozzle yes no

If nozzle requested please fill blew

Size: 1” 1.5” 2” 2.5”

Thread : Male female

Nozzle holes number-------PCS ,holes diameter ____mm

 

 

 

Send your message to this supplier