  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
welfare
cylinder capacity:
70L
cylinder color:
red
cylinder size:
1500* 267*5.7mm
inside gas weight:
45kg
storage pressure(20℃):
5.7MPa
Max working pressure(50℃):
14.4MPa
Supply Ability
Supply Ability:
100 Set/Sets per Month
Packaging & Delivery
Packaging Details
wooden case
Port
guangzhou

CO2 Fire suppression system parts

 

1.CO2 fire extinguishing system breif introduction:

 

CO2 Fire suppression system

The carbon dioxide is liquidized by high pressure and stored in cylinders, when spraying the 

carbon dioxide is expending sharply and absorbing a large quantity of heat, thus to reduce the 

temperature of the fire scene and dilute the oxygen level of the protected zone so as to put the 

fire out. Carbon dioxide is a inert gas, which is inexpensive, non-polluted, dissipated, and 

traceless. The carbon dioxide fire extinguishing system is able to put gas fire out after the gas 

supply source is cut, and it is also able to put out liquid fire, solid fire of fusible materials such as paraffin and asphalt, solid surface fire, deep-seated solid fire such as wincey, fabric, and paper, 

and electric fire, etc. The system is applicable to libraries, archives, database, bulk storages of 

liquid, computer rooms, communication rooms, generator rooms, substation rooms, oil immersionslots, mechanical mills, drying devices, and lacquer product lines. Note that carbon dioxide causes asphyxiation and the system shall be used where no people are involved. If the system takes 

effect in working places appropriate measures shall be taken to ensure safety.

The system puts out fires in a sealed room in a total flooding mode, it also works in a local application mode to put out non deep-seated fire of protected objects where sealed rooms are not 

required. The local application mode uses special nozzles which allow the extinguishing agent 

acts fully on combustion object directly, the system keeps supplying extinguishing agent on the 

combustion object for a certain time and intensity in order to put out the fire.

2.CO2 fire extinguishing system main accessoires:

1. Cylinder:

Volume: 70LTR        N.W :78KG
Diameter * height: 267*1700mm
Thickness: 5.7mm to 6.3mm
Working pressure: 15MPa,
Material: ” 37Mn
2. Cylinder valve:
Material: brass
Working pressure: 15MPa , thread: PZ39, hose thread: G5/8, release pressure:19 ±0.95
Consist of : valve body, gas chamber, pressure arm to sealing CO2.
In fire harzounds, controlled by manual, automatic open the valve to release to gas.
Valve connected with: dip tube, discharge hose.
3. Hose pressure hose: Dia: 12mm, working pressure: 15 MPa, thread G5/8, length:450 mm
4. Liquid one way valve: be used between manifold pipe and high pressure hose, prevent gas flow back to storage cylinder. Working pressure:15 MPa, valve actuated pressure: ≥0.15 MPa,

thread: M27/ G5/8.
Scale device gas loss: if less than 4kgs, output by signal, powder DC 24 V, rate voltage:1.5A
Manifold pipe: combinate all the stored cylinder, be installed cylinder racket.
Material: steel 20#, thread M27/M16, max working pressure: 15MPa
Safety release valve: be installed on manifold pipe, for release high pressure exceed the requested gas release:15± 0.75MPa, thread:M16
5. Selective valve: be used in combination system.
6. Pressure switch: be installed on manifold pipe (for independent system )
If selective installed on select outlet, when the gas are discharge, output on signal to control panel center actuated:0.2MPa, power:24DCV, rated voltage:1.5A
7. Pipe and connection: not supplier
8.Total flooding nozzle: terminal end of the pipe, discharge mouth for the agent with cover total flooding nozzle and no cover flooding nozzle, or side working nozzle dependent the designation.

 

 

3.CO2 Fire suppression system order instruction:

 

How you can get our offer ??

 

You are still in troubling get complex offer ?? Hope you meet three following situation

 

Case 1, If client can supply drawing layout .we can make free design and make offer to you within 24hours, pls send us your drawing room layout.

 

Case 2. If client has equipment list ?? pls contact us, we can make free design and make offer to you within 24hours

 

Case 3. No any drawing layout, no equipment list, then give us your room size: length X width X height and door information