Shenzhen PUSINUO Photoelectric Tech was established in 2014, which specialized in LED tubes, Panels, track light, downlight and so on. As a professional LED products manufacturer, we will keep pursueing customer first, innovation development policy.
3.Increased illumination output designed for elevated fxtures
4.UL Listed for factory and feld installation
5.Self-sensing output voltage operates various
6.product types reducing product SKUs for emergency options.
7.backlit panel emergency driver solution
8.UL CUL BC TITLE20 CEC CERTIFICATE
9.Microw inventer emergency driver
Safety Regulation:
Certificate
Approval Marks
Standard
Valid
Remarks
UL
UL924
YES
North America
cUL
CAN/CSA-C22.2 NO. 141
YES
Canada
BC
CEC Title 20
YES
California
FCC
FCC
YES
North America
DIMENSION:
Case- 12.36'' X2.28''X1.5 ''(314mmX58mm X38mm)
Mounting Center-11.8''(300mm)
Flexible Conduit 13''(330mm)
Case length
314mm
Case Height
38mm
Case Width
58mm
Mounting lenght
330mm
WIRING DIAGRAM:
1. Normal solution :When the led driver power less than the emergency power
5. With Sensor
Caution:
During AC operation, remember no touch or remove any wires in case of electric shock.
During emergency operation, before touching and disconnecting the wires, remember to
press the test button again to make the led lamp and indicator light off to avoid electric shock .
For the emergency led driver 15w work with LED lamp not more than 15w no need dimmable
function, and more than 15w need the dimmable function .The same as 25w and 40w.
The voltage input to thedimmable wires(DIM+,DIM-) of emergency LED drivermust less than 20Vdc.
For the emergency led driver 15w better work with LED lamp not more than 80w,for the
25w emergency led driver better work with led lamp not more than 150w ,for the 40w EM driver
must work with led lamp not more than 300w.
SELF-Diagnostic:
The integrated self-diagnostic circuitry will automatically conduct monthly 30-second and annual 90-minute tests to verify proper emergency capability per Life Safety Code requirements. Press the test button to the emergency mode with 30seconds, after 30seconds the fixtures turn into the AC mode automatically,when the emergency mode,press the test button turn off the emergency mode, then can disconnect the wire between emergency driver and fixtures . NFPA101, Life Safety Code outlines the following schedule: Monthly - Insure that the test button light is illuminated. Conduct a 30 second discharge test by depressing the test button.The LED load should operate at reduced output. Annually - Insure that the test button is illuminated. Conduct a full 90 minute discharge test. The unit should operate as into endedfor the duration of the test.“Written records of the testing shall be kept by the owner for inspection by the authority having jurisdiction.”
Our Service:
1.we provide our professsional engineer serivice for our clients.