Datasheet | ||||
Model Name | Solis-50K | Solis-60K-4G | ||
Input DC | ||||
Recommended max. PV power | 60kW | 72kW | ||
Max. input voltage | 1100V | |||
Rated voltage | 600V | |||
Start-up voltage | 200V | |||
MPPT voltage range | 200-1000V | |||
Max. input current | 4*28.5A | |||
Max. short circuit current | 4*44.5A | |||
MPPT number/Max. input strings number | 4/12 | |||
Output AC | ||||
Rated output power | 50kW | 60kW | ||
Max. apparent output power | 55kVA | 66kVA | ||
Max. output power | 55kW | 66kW | ||
Rated grid voltage | 3/N/PE, 220/380V, 230/400V | |||
Rated grid frequency | 50/60HZ | |||
Rated grid output current | 72.2A/76A | 86.6A/91.2A | ||
Max. output current | 83.3A | 100A | ||
Power Factor | >0.99 (0.8 leading - 0.8 lagging) | |||
THDi | <3% | |||
Efficiency | ||||
Max. efficiency | 98.8% | 99.0% | ||
EU efficiency | 98.4% | 98.5% | ||
Protection | ||||
DC reverse-polarity protection | Yes | |||
Short circuit protection | Yes | |||
Output over current protection | Yes | |||
Surge protection | Yes | |||
Grid monitoring | Yes | |||
Anti-islanding protection | Yes | |||
Temperature protection | Yes | |||
Strings monitoring | Yes | |||
Anti-PID function | Optional | |||
Integrated AFCI (DC arc-fault circuit protection) | Optional | |||
Integrated DC switch | Optional | |||
General Data | ||||
Dimensions (W*H*D) | 630*700*357 mm | |||
Weight | 63kg | |||
Topology | Transformerless | |||
Self consumption | <1W (night) | |||
Operating ambient temperature range | -25~ +60°C | -25~ +60°C | ||
Relative humidity | 0-100% | |||
Ingress protection | IP65 | |||
Cooling concept | Intelligent redundant fan-cooling | |||
Max. operation altitude | 4000m | |||
Grid connection standard | VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, RD 1699, UNE 206006, UNE 206007-1, IEC 61727, DEWA | |||
Safety/EMC standard | IEC 62109-1/-2, IEC 62116, EN 61000-6-2/-4 | |||
Features | ||||
DC connection | Universal PV Connector | |||
AC connection | OT terminal | |||
Display | LCD | |||
Communication | RS485, Optional: Wi-Fi, GPRS |
Payment Terms | T/T | EXW | 30% in advance for deposit payment, the balance payments will be paid before shipment. | ||||
FOB | |||||||
CFR/C&F | 30% in advance for deposit payment, the balance will be paid against copy of B/L | ||||||
CIF | |||||||
L/C | For the amount of one shipment above 50,000 usd, L/C at sight is acceptable. | ||||||
West Union | |||||||
Paypal | |||||||
Delivery Time | 7~25 days after receiving the payment or the deposit payment |
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items