Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware
- Model Number:
- AW-CFP2166
- Product name:
- 16 zone Fire alarm control panel
- Mains Supply Voltage:
- 110VAC or 240VAC
- Output Current:
- 3A@240VAC
- Battery:
- 12V2AH*2
- FaultOutput:
- NC and NO Relay
- Wiring Structure:
- 2-bus Wiring System
- Certificate:
- INTERTEK CE, SASO, ISO9001,EN 54 standard
- Max detector:
- 20pcs
- GSM module:
- fire alarm by SMS
- warranty:
- one year
- Supply Ability:
- 3000 Piece/Pieces per Month
- Packaging Details
- standard carton
- Port
- Shenzhen or Hongkong
16 zone conventional fire alarm panel (1-32 zone optional))
Intertek SASO and CE certificate
GSM module optional for fire alarm by SMS
AW-CFP 2166 Conventinal fire alarm panel 1 to 32 zone.
1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input .
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS .
ITEM | 1 Zone panel | 2 Zone panel | 4-8 Zone panel | 12-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
Power specification |
| |||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification |
| |||
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maximum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification |
| |||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 |
Picture:
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
* Our products are economic, user-friendly and easy maintenance.
* Prompt response.
* Standard quality control system.
* Independent R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Reliable after-sales service, with one year warranty.
2. Quality assuance and rliabilty
3. Professional and experienced R&D center can offer free technical support.
4. One year warranty and technical maintenance.
16 zone alarm control panel,16 zone conventional fire alarm control panel,fire alarm system control panel,wired alarm control panel,fire alarm panel conventional,fire alarm panel conventional
1. Packaging Details: EPE inside, carton outside
2. Shipping:delivered by air,ship or express for your order.
3. Delivery Time: 3-5 days after payment received