Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Type: |
Array |
Product Details
- Type:
- Biochemical Analysis System, discrete, fully automatic
- Brand Name:
- BIOBASE
- Model Number:
- BK-800(Emerald)
- Place of Origin:
- Shandong, China
- Name:
- Auto chemistry Analyzer
- Throughput:
- 800T/H
- Analysis Method:
- End-point, Fixed-time,Rate
- Certification:
- CE, FDA, ISO9001, ISO14001, ISO13485
- Programming Items:
- programmable for any test items
- Sample Types:
- Serum,plasma,urine,etc.
- Temperature Control:
- continuous2~8℃cooling within 24 hours
- Light Source:
- Halogen lamp, lamp can be auto sleep and wake up
- Power Supply:
- 110/220v ±10%, 50/60Hz
- Supply Ability:
- 500 Unit/Units per Month Auto Biochemistry Analyzer
- Packaging Details
- Exported wooden box
- Port
- Qingdao
- Lead Time:
- Shipped in 20 days after payment
Hot Selling BK-800 Emerald Auto chemistry Analyzer (800T/H) with Cheap Prices
1. Fully automated, Discrete, Random access,STAT priority,real-time dual wavelength.
2. Total open setting of items, supported different reagents from different countries.
3. Reversed optics and imported photo sensor make sure the precision of detection results.
4. Microsring injector imported from Germany assures the veracity of a trace of samples,
sample step by 0.1 UL, reagent step by0.5 UL
5. 24 hour non-stop working, convenient emergency function with inserting emergency at random.
6. Implementing analysis of ultra-trace reaction solution to 100 UL, and saving more reagents.
7. Discrete cuvette, preventing from cross-infection, and be washed and reused, making sure accurate result and save cost.
8. Perfect self-detection function makes sure the analyzer in order and accurate result.
9. Software is easy to learn and use. And test report can be printed.
10. Perfect function of quality control management is convenient for users to manage the clinical test result.
11. Detecting in the whole reaction process with reaction curve, convenient for users to monitor thoroughly
and scientifically analyze the detection data.
12. Supporting software can implement the function of detecting surplus reagent through liquid level
induction of reagent probe.
Overall Performance | Model | BK-800(EMERALD) | ||
Type | Discrete, Fully automatic | |||
Throughput | 800 tests per hour | |||
Analysis Method | End-point, Fixed-time, Rate, Turbidimetry | |||
Programming Items | Programmable for any test items | |||
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |||
Sample unit | Sample Position | 180 samples, double disk design, including 60 samples for calibration/quality dribbling refrigerated | ||
Sample Tubes | Original blood collection tube, micro tube, plastic tube, etc | |||
Sample Types | Serum, plasma, urine, etc | |||
Sample Volume | 2ul ~70ul (0.1ul stepping) | |||
Sample Probe | Having liquid level induction function, ensuring the accuracy of adding sample | |||
Probe Cleaning | Automatic washing both interior and exterior , cross contamination rate < 0.1% | |||
Analysis Items | Analyzing maximally 100 items at the same time | |||
Reagent unit | Reagent Position | 200 reagent positions, dual-tray design | ||
Wash Solution | Washing solution can be installed in any position, including needle, stir bar washing solution and water bath disinfectant | |||
Reagent Volume | 20ul~350ul, 0.5ul increment | |||
Temperature Control | Continuous 2℃~8℃ cooling within 24 hours | |||
Reagent Probe | Having liquid level induction function, ensuring the accuracy of adding reagent. Inventory checking | |||
Probe Cleaning | Automatic washing both interior and exterior | |||
Reaction Unit | Reaction Volume | 150ul-550ul | Reaction Temperature | 37℃ |
Temperature System | Water bath,Real-time temperature display | |||
Cuvettes | 160 positions with permanent hard glass cuvettes (optical path length 5mm) | |||
Stirrer | Independent stir bar, nanotechnology, highly polished, automatic frequency conversion | |||
Cleaning | Automatic water cleaning and drying system | |||
System Adjustment | System can record the blank value and get more accurate result by deducting blank base value of each cuvette | |||
Optical System | Light Source | Halogen lamp, lamp can be auto sleep and wake up | ||
Receiver | Holographic flat field concave grating diode array detection | |||
Wavelength Range | 16 wavelengths from 340 to 800nm | |||
Linear Range | -0.3000~3.3000 Abs | |||
Stray Light | < 0.1% or Abs > 3.0 | |||
Calibration and QC | Calibration Method | Linear calibration:K factor, two- and multiple linear Nonlinear Calibration: spline, polynomial, Logarithm, etc | ||
Quality Control | Auto QC,cooled QC positions | |||
Software | Emergency Function | Emergency sample can be placed in the sample tray at any time | ||
Software | Windows 7/8/10 or above, LIS system available | |||
Online | Full bi-directional communication possible | |||
Data Processing | Having reaction curve detection and data display function in the whole process | |||
Others | Water Consumption | Deionized water , <45 L/hour | ||
Power Supply | 110/220v ±10%, 50/60Hz | |||
Package Size | 1720*1200*1430mm | |||
Gross Weight | 600Kg |
With a wooden or cardboard boxes, strong packing, you can choose Ocean shipping,air transport or express.
Pre-sale service
- 24hours online to ensure quick response to customers" inquiry or online message;
- Guide customers to choose the best suitable machine model;
- Offer detailed specification and competitive prices;
Contract execution
- Machine production will be arranged strictly according to the contract;
- Machine photos will be sent to you for inspection during production;
- Update latest news after delivery and prepare customs clearance;
After-sale service
- Broken spare parts (except for wear parts) will be sent for free due to quality problems;
- In time response to customers technical problems;
- New products update for customers" reference
BIOBASE group, founded in 1999 and been through high and stable development for 15 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.The products we manufacture extends to most of the laboratory items and scientific analytical equipments. Our mission is to enable our customers to make the world healthier, cleaner and safer.BIOBASE group invests in science and technology research, aim to keep impoving products performance and quality as well as develop new products to meet customers wide requirement.
FAQ for better and easy cooperation
1.Why choose BIOBASE ?
We are the leading manufacture,OEM&ODM service are offered.
2.How about the sample of BIOBASE product ?
We could send you the samples but the freight and the sample are charged.
3.How about BIOBASE payment term ?
T/T & L/C & Western Union(40% deposit, the balance before shipment).
4.How about BIOBASE delivery time ?
Within 7-15 workdays after receiving deposit.
5.How about BIOBASE validity of quotation ?
Usually 30 days as the shipping freight and exchange rate can be fluctuant.
6.What is the shipping port ?
FOB to Qingdao Port, China (also can ship according to customers’ request).
7.How about the package ?
Bubble film +Cotton+Standard export wooden case.
8.How to inspect the goods ?
Products will be checked by our QC staff first,then our project manager.Client can come and check by themselves or third party check is available.
Customer Reviews total 0 items