Technical Specification
Model | SUN-5K-SG01LP1 | SUN-6K-SG01LP1 | SUN-7.6K-SG01LP1 | SUN-8K-SG01LP1 | |||
Battery Input Data | |||||||
Battery Type | Lead-acid or Lithium-ion | ||||||
Battery Voltage Range (V) | 40~60V | ||||||
Max. Charging Current (A) | 120A | 135A | 190A | 190A | |||
Max. Discharging Current (A) | 120A | 135A | 190A | 190A | |||
Charging Curve | 3 Stages / Equalization | ||||||
External Temperature Sensor | Optional | ||||||
Charging Strategy for Li-Ion Battery | Self-adaption to BMS | ||||||
PV String Input Data | |||||||
Max. DC Input Power (W) | 6500W | 7800W | 9880W | 10400W | |||
PV Input Voltage (V) | 370V (100V~500V) | ||||||
MPPT Range (V) | 125V-425V | ||||||
Start-up Voltage (V) | 150V | ||||||
PV Input Current (A) | 11A+11A | 22A+11A | 22A+22A | 22A+22A | |||
No.of MPPT Trackers | 2 | ||||||
No.of Strings Per MPPT Tracker | 1+1 | 2+1 | 2+2 | 2+2 | |||
AC Output Data | |||||||
Rated AC Output and UPS Power (W) | 5000W | 6000W | 7600W | 8000W | |||
Max. AC Output Power (W) | 5500W | 6600W | 8360W | 8800W | |||
Peak Power (off grid) | 2 times of rated power, 10 S | ||||||
AC Output Rated Current (A) | 20.8A | 25A | 31.7A / 33A | 33.4A / 35A | |||
Max. AC Current (A) | 22.9A | 27.5A | 34.9A / 36.3A | 36.7A / 38.5A | |||
Max. Continuous AC Passthrough (A) | 35A | 40A | 50A | 50A | |||
Output Frequency and Voltage | 50 / 60Hz;208Vac (2 / 3 phase), 230Vac (single phase) | ||||||
Grid Type | 2 / 3 phase; Single Phase | ||||||
Current Harmonic Distortion | THD<3%(Linear load<1.5%) | ||||||
Efficiency | |||||||
Max. Efficiency | 97.60% | ||||||
Euro Efficiency | 97.00% | ||||||
MPPT Efficiency | 99.90% | ||||||
Protection | |||||||
PV Input Lightning Protection | Integrated | ||||||
Anti-islanding Protection | Integrated | ||||||
PV String Input Reverse Polarity Protection | Integrated | ||||||
Insulation Resistor Detection | Integrated | ||||||
Residual Current Monitoring Unit | Integrated | ||||||
Output Over Current Protection | Integrated | ||||||
Output Shorted Protection | Integrated | ||||||
Output Over Voltage Protection | Integrated | ||||||
Surge protection | DC Type II / AC Type II | ||||||
Certifications and Standards | |||||||
Grid Regulation | UL1741, IEEE1547, RULE21, VDE 0126, AS4777, NRS2017, G98, G99, IEC61683, IEC62116, IEC61727 | ||||||
Safety Regulation | IEC62109-1, IEC62109-2 | ||||||
EMC | EN61000-6-1, EN61000-6-3, FCC 15 class B | ||||||
General Data | |||||||
Operating Temperature Range (℃) | -25~60℃>45℃ Derating | ||||||
Cooling | Smart cooling | ||||||
Noise (dB) | <30 dB | ||||||
Communication with BMS | RS485; CAN | ||||||
Weight (kg) | 32 | ||||||
Size (mm) | 420W×670H×233D | ||||||
Protection Degree | IP65 | ||||||
Installation Style | Wall-mounted | ||||||
Warranty | 5 years |