Domestic Market 30.00%
Africa 12.00%
Southeast Asia 10.00%
Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Number | Trouble | Cause | Shooting |
1 | Motor of Barrier does not work | 1,No power supply | 1,Check power supply |
2,Break fuse | 2,Change fuse | ||
3,Motor is damaged | 3,Change the motor | ||
2 | Barrier can open but can not close | 1,Photocell is not connected properly | 1,Connect the photocell |
2,Photocell beam is block off | 2,Clear out obstacle | ||
3,Photocell is broken | 3,Change a new device | ||
3 | 1,Position of limit switch is not correct | 1,Adjust position | |
2,Limit switch is damaged | 2,Change limit switch | ||
4 | 1,Distance of limit switch is too large | 1,Adjust position of limit switch | |
2,Limit switch is wrong | 2,Change limit switch | ||
3,Magnetic-stell’s position is wrong | 3,Re-adjust the position | ||
5 | Release device of Barrier is doesn’t work | 1,Operating handle is broken | 1,Change the handle |
2,Worm gears are jammed | 2,Rotate the pinion | ||
6 | Push the “OPEN” button but the Barrier gate close | Whether “+MOTOR-” wires are connected wrong | Connect correctly according to wiring diagram |
7 | Motor of Barrier can work but boom can not work | Compression spring of clutch is dead | Change the spring |
For product pricing, customiztion, or other inquiries
Contact Supplier