Intelligent Multi-function Current Protector Voltage Protection device stabilizers

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-11-19 19:18

Other Products
LC1-D0910 Motor Contactor
¥Negotiable 8Views

LC1-D0910 Motor Contactor

Recommend  
Magnetic Contactor LC1-D65 AC Contactor in Contactors
¥Negotiable 10Views

Magnetic Contactor LC1-D65 A

Recommend  
LP 25-24 Single output LED display Din-Rail Switching Power Supply 24W 24V 1A
¥Negotiable 8Views

LP 25-24 Single output LED d

Recommend  
LP 25-5 Single output LED display Din-Rail Switching Power Supply 20W 5V
¥Negotiable 9Views

LP 25-5 Single output LED di

Recommend  
LP 25-12 Single output LED display Din-Rail Switching Power Supply 25.2W 12V 2A
¥Negotiable 11Views

LP 25-12 Single output LED d

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
winston
Model Number:
WD-E63
Usage:
SVC
Phase:
Single Phase
Current Type:
AC
Rated current:
Adjustable between 1A-63A (63A default)
Under-voltage protection value range:
OFF-210V-150V (adjustable), 160V (default)
Over-voltage protection value range:
221V-300V-OFF (adjustable), 280V (default)
Recovery delay time:
2s-512s (Default 60s)
Delay time for power-on:
2s-255s (Default 2s)
malignant load protective current:
0.5A-5A (Default 5A)
Scope of electric energy measuring:
99999KW.h
Leakage protection value:
2mA-30mA (Default 20mA)
leakage actuation time:
0.1 second
Supply Ability
Supply Ability:
20000 Piece/Pieces per Month
Packaging & Delivery
Port
ningbo
Lead Time:
Quantity(Pieces)1 - 20000 >20000
Est. Time(days)30To be negotiated

Intelligent Multi-function Current Protector Voltage Protection device stabilizers

 

I. Purpose

   Intelligent multi-function current protector is a comprehensive intelligent protector integrating severalfunctions including electric energy measuring, overcurrent protection, over-/under-voltage protection, resistance(malignant load) protection and leakage protection. In case over-current, over-/under-voltage, or leakage fault occurs in the circuit, the protector can instantaneously cut off the power and protect the electrical equipment fromburning-out. When all lines return to normal state, the protector can automatically restore power. The parameters of this protector, such as over-current value, over-/under-voltage value, leakage current value, resistance(malignant load) current value, actuation time and recovery time, etc., can be setting as needed. It still possessesthe function of fault memory and inquiry as well as factory data reset. The real-time voltage value and current value and electric energy value are displayed cyclically. Each time you press the button"", the voltage, current and electric energy to be displayed separately while you press the button"", all the alternatives can be display. Itis so flexible that it can be used as a voltmeter, ammeter or coulombmeter. Users can choose the appropriate type of protector according to the actual situation.

II. Main technical parameters

Product model

WD-E63

Rated voltage

230V50Hz

Rated current

1A ~ 63A (adjustable), 63A (default)

Under-voltage protection value range

OFF-210V-150V (adjustable), 160V (default)

Over-voltage protection value range

221V-300V-OFF (adjustable), 280V (default)

Recovery delay time

2 ~ 512s   (Default 60s)

Delay time for power-on

2 ~ 255s (Default 2s)

malignant load protective current

0.5-5A (Default 5A)

Scope of electric energy measuring

99999KW.h

Leakage protection value

2-30mA(Default 20mA)

leakage actuation time

0.1s

Power consumption

≤2W

Electrical and mechanical lifespan

≥40 thousand times

 

III.Product Dimensions

IV.Product introduction

V.Product connection diagram

 

 VI.Normal service conditions and installation environment

  1. The ambient air temperature shall not exceed +40℃ to -5℃, and the 24-hour average shall not exceed +35℃.

  2. The relative humidity of the air at the installation position shall not exceed 50% when the ambient airtemperature is +40℃, Higher relative humidity can be obtained at a lower temperature, for example: When theaverage minimum temperature of the month with the highest humidity is +20℃, the average maximum relative humidity of the month will reach 90%. Appropriate measures should be taken to prevent the condensation due totemperature change.

  3. The altitude of the installation position shall not exceed 2,000m.

  4. The protector shall be installed in the medium free from explosion hazard and gas or conductive dust that areable to corrode metals and destroy the insulation.

  5. The protector shall be installed in the position where there is no rain or snow.

VII. Announcements

  1. When carrying out various operations or tests, you shall follow the relevant procedures and focus on thefollowing items to ensure proper and safe use.

  2. Wire the input and output ends properly according to the product identification.

  3. Line conductors shall meet the relevant current standard values, and the load current shall not exceed the maximum protection current values of the protector.

  4. The neutral line N shall be connected properly and securely. The zero line N of the protector shall be directlyconnected, and it has no disconnection function.

  5. Check the wiring carefully before powering on.

  6. After the product is powered on, do not touch the live parts to avoid electric shock accidents.

  7. This protector has no short-circuit protection function and it shall work with miniature circuit breaker. If the miniature circuit breaker is not used for protection, the short circuit current will not be broken when there is a short circuit fault at the input or output ends of the protector.

  8. The protector has self-resetting function. After the overcurrent protector performs protection anddisconnection, the load appliance shall be removed immediately, and the circuit line shall be checked. Otherwise, the protector will frequently switch on the load appliance, which will eventually damage the electrical applianceand the protector body.

  9. The protector has no isolation function. It shall work with the miniature circuit breaker, and break off theformer circuit breaker switch when repairing the circuit line.

  10. Notice! When the breaking time of under-voltage exceeds 0.2 seconds, the protector will not open afterthe power fault. (MCU will not work with power lossing after 0.2 seconds of power fault)

VIII.Different between others