Long range smoke detector beam system

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 03:19

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 9Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 16Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 15Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 12Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 19Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-BK901
Usage:
Fire, warehouse office factory
Nature:
conventional
Color:
white
Monitoring Distance:
40m-100m
Product name:
Long range smoke detector beam system
Design:
OEM ODM
Wiring Method:
2 wire bus
Certificates:
CE ROHS ISO9001 for beam smoke detector
Dimension:
206mm*95mm*95 mm
Charactor:
High sensitive
Supply Ability
Supply Ability:
1000000 Piece/Pieces per Year negotiable for beam system
Packaging & Delivery
Packaging Details
beam systemfoma to pack well
Port
shenzhen

 Long range smoke detector beam system   

   Beam system   Fire Detector is a Long-interval reflection line infrared beam system  , which must be used together with a reflector.

 

 In case of smoke on the light path of the detector, the signal arriving at the receiver is reduced;

 

--when the light reduction rate reaches the preset threshold, the detector will produce the alarm signal;

 

--when the light beam is completely blocked, the detector will produce the fault signal to prevent the false alarm caused by non-fire blockage.

 

 

 

The whole system of  beam system

 

Parameters of beam alarm

Beam  alarm distance40m/70m/100m
working enviroment beam smoke detector

Warehouse goverment building  school hospital comercial building

operating voltage

DC16V~DC32V

External dimension

206mm×95mm×95 mm

 Weight

 450g

 

Certificate of liner 40m to 100m beam system  

Delivery express for 40m to 100m  beam system  

 