Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- EVEN/OEM
- Bulb Type:
- LED/Fluorescent
- Battery Type:
- Ni-CD/Ni-MH/Li-ion
- Material:
- Cold Rolled Steel Sheet
- Usage:
- Emergency
- Certification:
- CE/RoHs
- Specifications:
- For LED/Fluorescent
- Type:
- Low voltage inverter
- Charging Time:
- 24Hrs
- Emergency Duration:
- 3hours
- Battery Capacity:
- 3.0Ah*10(Custom)
- Inverter type:
- High Voltage
- Amblent Temp:
- 0℃-55℃
- Em.Power:
- 10-100% illumination
- Model:
- Maintained
- Application:
- Emergency
- Accessaries:
- Metal Box/IP65 box
- Supply Ability:
- 999999999 Pack/Packs per Day Low voltage inverter
- Packaging Details
- Low voltage inverter insulated package
- Port
- Shenzhen/Hongkong
- Lead Time:
Quantity(Pieces) 1 - 31 32 - 100 101 - 5000 >5000 Est. Time(days) 12 15 20 To be negotiated
Low voltage inverter emergency 18w 25w led emergency light conversion kit for led panel
Model No. | EMI-LT |
Product Name | Full emergency power |
Battery Type | NiMH, NiCd Li-ion |
Lighting Power | T5/T8 led tube |
Emergency Power | 0-50W |
Input voltage | AC85~265V, 50/60Hz |
Battery protection | Yes |
Operation temperature | -20--70℃ , 65+20% RH |
Highest Surface Temperature | 50°C |
Battery Capacity | 12V 2000mAh Rechargeable Nicd battery pack |
Charging Time | >24h without break |
Output Voltage in emergency | DC220-310V |
Suitable light source | LED tube |
Emergency power | 100% |
Emergency duration | 120 minutes |
Product Weight | 1.5kgs |
Inverter dimension | 180*40*30mm |
Outer casing size | According to battery’s series |
Note | Custom-Made battery to be configured with different back-up period and different light output levels. |
Description
EMI-LT Tube light led emergency kits built in power pack is full emergency output module. To be installed inside of led tube housing for more convenient and easy usage.
The converter automatically adjusts the output LED current and keeps Fixed Voltage output to provide the best match between the battery and the load, providing maximum illumination whilst ensuring full battery duration.
The product range to cover a variety of LED fixture ideal for high voltage board(220-310V DC)LED tube, Led Sensor tube and Tri-proof tube...etc with internal LED driver.
Features
- IC controlled Dual rate Charger for energy savings.
- Short circuit protection at battery terminals.
- Battery reverse protection functionality
- Charge indicator and test button. The light fittings guarantee safety of people in buildings open to the general public.
- Automatically actuated in the event of power cuts, these devices (kit + light fitting) offer a good luminous flux to facilitate the evacuation.
- Comply with European standards EN 61 347-2-7 and offer a high level of quality and safety meeting the various prevailing regulations.
- 100% emergency power output ,Dial the code to suitable current of luminaires.
For example low voltage emergency pack as following for your reference(more other type,pls contact EVEN :
3.Product details :
LED Strip : 24W
Output Voltage :DC12V
Output Current : 2A
4.Emergency Solution:
1. According to EN60598; EN 55015; CE;
2. Deep discharge protection
3. Operation time (discharge):1hour(Customized within 1hr)
4.Lumen Factor : 50%
5.Emergency Output:DC12V/1A
6.Matched Emergency Solution : 6V/2.5Ah Ni-CD Battery + Inverter+ Metal Box+ Inner Box
5. Dimension (mm ):
Battery Size : C type (50*25mm/cell)
Inverter Size : 155*40*30mm
6.Application:
Product name: Emergency module for LED Strip
7.Specifications of Drawing, Schedule and Symbols:
L = “live”wire
N= “Neutral” wire sometimes called “nil” or “0”
Switch = a mechanical device that connects or interrupts a “life”wire to the driver.
LED Driver is an electronic device that drives the LED lighting fixture with a constant current.
SL is switched Life wire connection on the LED driver
N is the Neutral connection on the LED driver
+ on the LED driver is the positive connection from driver to the LED fixture
- on the LED driver is the negative connection from driver to the LED fixture
8.Usage range :
1Hotels
2Conference/Meeting rooms
3Factories & Offices
4Commercial Purposes
5Residential/Institution Buildings
6Schools, Colleges & Universities
7Hospitals
8Places where energy saving and high color rendering index lightings are required
9.Installation Instruction:
-Connection 1 is used for safety ground (earth)
-Connection 2 is used for connecting to the life wire of the buildings electricity network before the
switch, sensing if the life wire is “alife”
-Connection 3 is used for connecting the neutral of the buildings electricity network
-Connection 4, 5 and 6 are not used. Or connect “L” of building electricity to connection 4(SL),
and connect Driver “L”,”N”with connection 5 and 6.
-Connection 7 and 8 have a test switch
-Connection 9 (positive +) and 10 (negative -) for connecting a control LED meaning Life
electricity is connected and “alive”.
-Connection 11 (positive +) and 12 (negative -) are used to connect the battery for emergency
operation.
-Connection 13 (positive +) and 14 (negative -) are used to connect the LED system driver.
-Connection 15 (positive +) and 16 (negative -) are used to connect the LED fixture to the current driver of the module.
10.Operation
The module is capable of testing the performance of the emergency luminaire in accordance with
IEC EN61347-2-7 & EN61347-2-13.
11.Commissioning Test
Connection of the mains supply will initiate commissioning where the battery will remain on charge for an uninterrupted 24 hours. An interruption of the mains supply will impact the accuracy of emergency running duration.
12.Functional test
This test can be initiated manually by pressing the Testing Button.
13.Duration Test
A full rated duration test is carried out after charge the battery for 24 hours.
Note that start times of the tests are set based on the battery capacity.
14.Charge LED Indicator
A range of LEDs are available in red or green, diffused or clear high intensity, with or without a fitted rubber bezel or plastic clip and with various lead lengths.Check the LED charge indicator is on with the mains present and battery is being charged while inverter is working well.
Attentions:
- Pay extra attention to the negative and the positive pole of the battery in order to prevent
reverse operation, please use designated and matching batteries and ensure all wiring is done
correctly and stable before use.
- If you need to do product testing, unplug the battery pack when the emergency device is
disconnected from the mains supply, and then plug in the battery after the emergency device is
completely shut down.
- Comply with the wiring connection circuit diagram completely, prevent from over loading and
non loading in the process of use and testing.
- In order to prolong the battery powered lighting time, all indicator lights are switched off
during normal use with the emergency power system in standby mode.
- The battery is not charged before leaving the factory; please charge the battery longer than 24
hours before use.
- In general, the battery needs to be fully charged and discharged for around 3- 5 times in order
for the Ni-CD/Ni-MH battery to operate at full capacity.
8- It is detrimental for the Ni-CD/Ni-MH battery to lie idle for a long time, especially when it runs
dead. Charge the battery completely when it is out of operation for a long time. (The battery cannot
lie idle for more than three months)
Important:
It is recommended that the module is installed by a competent person ensuring the installation complies with the necessary standards. EVEN accepts no responsibility for injury, damage or loss, which may arise as a result of incorrect installation, operation or maintenance. the conversion requires an unswitched supply for charging the battery and a switched supply for a maintained conversion.Ensure that the finished converted luminaire operates within the module and battery temperature ratings.Ensure that the original luminaire components are still operating within their temperature ratings.
Note the production date of the battery.
-Charge the battery completely when it is out of operation over 3 month.
-Check the emergency module functionality for 3 month intervals.
-Replace the battery every 3 years interval
Why Choosing Us
LED lighting plays a key important role in daily life,accordingly,the emergency kit is also important within this products.
Emergency Lighting Inverters need professional understanding of battery specification to get good performance. We develop our inverters inch by inch to best fit lights and battery.
Therefore, rather than its price, the reliability is the top factor to consider.
More experiences we have,more professional will service for you.
You are most welcome to contact us by Skype, e-mail, telephone call or even walk in to talk to us. We will try best to get best solution for you.
OEM/ODM for wholesales and retailers who need emergency project.
Customer Reviews total 0 items