Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Type: |
Array |
China
Long Term
2019-10-17 01:18
Scan By Phone
Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Type: |
Array |
New design Emergency converter for LED panel SELV output voltage output voltage
If you want to match IP65 outer box,more dimension for your option.pls contact EVEN.Thanks for your support.
Note : Parameters on the inverter/battery will be changed according to your lighting when get your cofonfirmed.Emergency Box"s includes inverter,battery pack and some accessories.
Type | Emergency Backup Kit |
Battery Pack | Ni-CD/Ni-MH/Li-ion |
Emergency Duration | 1-3 hours |
Brightness | 10-100% |
Outer box | Metal Box/Plastic box/IP65 case/Aluminum Box |
Product description
Emergency lighting LED Driver for manual testing
For LED modules with a forward voltage of 10 – 60 V
SELV for output voltage < 60 V DC
Low profile casing (21 x 30 mm cross-section)
For luminaire installation
5-year guarantee
Standards
according to EN 50172
according to EN 60598-2-22
EN 61347-1:2008+A2:2013
EN 61347-2-13
EN 61347-2-7
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61547
EN 60068-2-64
EN 60068-2-29
EN 60068-2-30
EN 62384
Properties
Non maintained operation
1 or 3 h rated duration
Compatible with all dimmable and non-dimmable constant current LED Driver
3-pole technology : 2-pole LED module changeover and delayed power switching for the LED Driver
Automatic shutdown of output if LED load is out of range
Constant power output
Maximum light output for all LED modules
Electronic charge system
Deep discharge protection
Short-circuit-proof battery connection
Polarity reversal protection for battery
Batteries
High-temperature cells
NiCd or NiMH batteries
D, C or SC cells
4-year design life
2-year guarantee
Technical data
Rated supply voltage 220 – 240 V
Mains frequency 50 / 60 Hz
Typ. λ (at 230 V, 50 Hz) 0.6
LED module forward voltage range 10 – 60 V
EM output power 3W
EM output current see next follow table
Time to light < 0.2 s from detection of emergency event
Overvoltage protection 380 V (for 1 h)
Maximum output voltage 60 V
Battery charging time 20 h
Ambient temperature range ta -5 ... + 55 °C
Max. casing temperature tc 70 °C
Mains voltage changeover threshold according to EN 60598-2-22
Type of protection IP20
2.Wiring Diagram
Certificates :
Business Office :
For product pricing, customiztion, or other inquiries