PFC function 1200w 12v ac regulated dc 100 amp switching power supply
Features:
1,With wide application,they had been used in LED lighting,ACS,medical and beauty device,electrical power system,communication system,military industry and others.
2,Some models achieved GS,CE,CCC,ETL,ISO,ROHS certification now.
3,There are more than 1,000 kinds of models.
1,Small size,high efficiency; |
||||||||
2,International universal full voltage input; |
||||||||
3,Built-in active PFC function; |
||||||||
4,Built in filter,low noise,high reliability; |
||||||||
5,Overload, short circuit, under voltage, over voltage, over temperature and other protection functions. |
||||||||
parameter Item No. |
K57-UP1200S12F |
K57-UP1200S24F |
K57-UP1200S30F |
K57-UP1200S36F |
K57-UP1200S48F |
|||
OUTPUT
|
DC Output Voltage |
+12V | +24V |
+30V |
+36V |
+48V |
||
Rated Current |
100A | 50A | 40A | 33.4A | 25A | |||
Rated Power |
1200W | 1200W | 1200W | 1202.4W | 1200W | |||
Ripple & Noise |
200mVp-p | 250mVp-p | 300mVp-p | 350mVp-p | 400mVp-p | |||
ADJ.output range |
11.4-12.6V | 22.8-25.2V | 28.5-31.5V | 34.2-37.8V | 45.6-50.4V | |||
Output Accuracy |
±1% | ±1% | ±1% | ±1% | ±1% | |||
Line Regulation |
±0.5% |
|||||||
Load Regulation |
±0.5% |
|||||||
Set up,rise,keep up time |
500ms,50ms,12ms |
|||||||
INPUT
|
Input Voltage range |
100V~240V AC |
||||||
Input Current |
5.8A/@230VAC 13.5A@100VAC |
|||||||
Input Frequency |
50-60Hz |
|||||||
Power Factor |
PF>0.98/115V or PF>0.95/230V |
|||||||
Efficiency |
94% |
95% |
95% |
95.5% |
96% |
|||
Inrush Current |
Cold start 60A/230Vac |
|||||||
Leakage Current |
<0.5mA@240V |
|||||||
PROTECTION |
Over Load Protection |
105~150% Hiccup protection,automatic recovery |
||||||
Short Circuit Protection |
Locked protection,need to power off for 1min,return to normal after restart |
|||||||
Output Over-voltage Protection |
>120% Shut down,Locked protection, return to normal after restart |
|||||||
Output under-voltage protection |
<70VAC It will be protection, then automatic recovery |
|||||||
Over Temp. | TS1 position>105℃ it will be protection, then automatic recovery | |||||||
ENVIRONMENT
|
Working Temp.,Humidity |
-20~60 ℃,10~90% RH , No condensation |
||||||
Storage Temp.,Humidity |
-20~85℃,10~95% RH. |
|||||||
Temperature Drift |
±0.03%/℃(0~50℃) |
|||||||
Vibration |
10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACHAXES |
|||||||
SAFETY&EMC
|
Safety Standards |
GB4943-1, EN60950-1,EN62368-1 |
||||||
Withstand Voltage |
I/P-O/P:3KV; I/P-FG:1.8KV;O/P-FG:0.6KV AC 1min. |
|||||||
Insulation Resistance |
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms |
|||||||
EMC Standards |
EN55032 CLASS A |
|||||||
OTHER
|
Dimension |
230*127*42mm (L*W*H) Do not contain terminal |
||||||
Weight |
1.5Kg |
|||||||
MTBF |
>50K hrs ,MIL-HDBK-217F(25℃) |
Fan Supply |
12V/0.3A for driving fan,tolerance±15%,built-in fan forces air cooling |
Note: |
1.All parameter 230VAC input,rated load,environment temperature 25℃,measured under conditions of 70% humidity; 2.Accuracy: including set up tolerance,line regulation,Load regulation etc; 3.Ripple test: 30cm long wire connect power supply and load, load end parallel 0.1u and 47u capacitor,the 20MHz oscilloscope was measured at the load end; 4.Line regulation: at rated load conditions, the input voltage change from low to high measured; 5.Load adjustment rate: measured output measured from 0 load to 100% load change. |
Payment&Shipping Payment Shipping |
Q1. Can I have a sample order for power supply?
A1: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
Q2: Do you accept OEM/ODM for the switching power supply ?
A2: Yes. we do.
Q3:How about the quality?
A3:We have the better professional and experienced engineers team and strict QA and QC system.Repair rate under 0.1%~0.2%
Q4:What is PFC?
A4:PFC stands for Power Factor Correction. The purpose of PFC is to improve the ratio of apparent power and real power. The power factor is only 0.5~0.7 in non-PFC models. In PFC models, the power factor can reach above 0.9. The calculation formulas are as below:
Apparent Power=Input Voltage x Input Current (VA)
Real Power= Input Voltage x Input Current x Power Factor (W)