DC Series
AGM Deep Cycle VRLA Batteries
Voltage class: 2V/6V/12V
Capacity range: 26Ah~3000Ah
Superior deep cycle design
Suitable for solar & wind energy, UPS, telecom systems, electric power systems, control systems, golf cars, etc.
Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Model | DC12-26~DC12-260 | DC2-200~DC2-3000 | FT12-55D~FT12-185D | ||
Cells Per Unit | 6 | 1 | 6 | ||
Voltage Per Unit | 12V | 2V | 12V | ||
Terminal | F3(M5) / F13-BP(M5)/T24(M5)/F5(M8) / F12(M8) | F10(M8) | F9(M8)/F14(M8) | ||
Design Life | 12 years (floating charge) | 20 years (floating charge) | 12 years (floating charge) | ||
Float Charging Voltage | 13.6 V~13.8 V @ 25℃ Temperature Compensation: -3mV/℃/Cell | 2.27 V~2.30 V @ 25℃ Temperature Compensation: -3mV/℃/Cell | 13.6 V~13.8 V @ 25℃ Temperature Compensation: -3mV/℃/Cell | ||
Cycle Use Voltage | 14.6 V~14.8 V @ 25℃ Temperature Compensation: -4mV/℃/Cell | 2.43 V~2.47 V @ 25℃ Temperature Compensation: -4mV/℃/Cell | 14.6 V~14.8 V @ 25℃ Temperature Compensation: -4mV/℃/Cell | ||
Operating Temperature Range | Discharge: -20℃~60℃;Charge: 0℃~50℃;Storage: -20℃~60℃ | ||||
Normal Operating Temperature Range | 25℃±5℃ | ||||
Self Discharge | RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored for up to 6 months at 25℃ and then recharging is recommended. Monthly Self-discharge ratio is less than 3% at 25℃.Please charged batteries before using. | ||||
Container Material | A.B.S. |
Battery Rating | Warranty Period | ||||||
AGM VRLA Batteries. 12V 1.2Ah, to 12V 28AH;6V 1.3Ah, to 6V 12Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | ||||||
AGM VRLA Batteries. 12V 33Ah, to 12V 250AH;2V 100Ah, to 2V 3000Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | ||||||
AGM VRLA Deep Cycle Batteries. 12V 65Ah, to 12V 250AH;2V 200Ah, to 2V 3000Ah | 24 months from installation or 25 months from date of supply from company whichever is earlier | ||||||
GEL VRLA Batteries. 12V 33AH,to 12V 250AH | 36 months from installation or 37 months from date of supply from company whichever is earlier | ||||||
GEL VRLA Batteries. 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier | ||||||
Tubular Gel Batteries. OPzV 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier (Optional)60 months from installation or 61 months from date of supply from company whichever is earlier | ||||||
Tubular Flooded Batteries. OPzS 2V 200AH,to 2V 3000AH | 36 months from installation or 37 months from date of supply from company whichever is earlier |
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items