S Series | |
DR Series | |
MDR Series 10W 40W 60W 100W | |
LPV Series 15W 20W 30W 50W 60W 100W 150W 200W 250W | |
NES Series 15W 25W 35W 50W 75W 100W 150W 200W 350W | |
LRS Series 35W 50W 75W 100W 150W 200W 350W | |
PFC Function Series SP-75W SP-100W SP-150W SP-200W SP-320W SP-500W | |
MS Series 15W 25W 35W 50W 60W 75W 100W 120W 150W | |
More |
Features:
.Small volume, low weight, high efficiency
.Protections:short circuit/over load/Battery Charge
.Indicator for power on/charge/normal(LED)
.100% full load burn-in test
. Battery protection at low voltage
. 2 Year warranty.
Model | SC-60-12 | SC-60-24 | |||
Output | DC voltage | CH1:13.8V | CH1:13.4V | CH1:27.6V | CH2:26.5V |
Voltage tolerance | ±1% | ----- | ±1% | ----- | |
Rated current | 4.0A | 0.35A | 2.0A | 0.25A | |
Current range | 0~4A | ----- | 0~2A | ----- | |
Rated power | 59.9W | 61.8W | |||
Ripple&noise | 100mvp-p | ----- | 100mvp-p | ----- | |
DCvoltage ADJ.range | CH1:11.3~14.9V | CH1:21.3~29.8V | |||
Input | Voltage range | 90~264VAC, 127~370VDC | |||
frequency | 47~63HZ | ||||
AC current | 1.6A/115VAC, 0.8A/230VAC | ||||
Efficiency | 81% | 83% | |||
Inrush current | Cold start current 25A/115VAC,45A/230VAC | ||||
Leakage current | < 1mA/240VAC | ||||
Protection | Over load | Rated output power110%~150% start over load protection | |||
Protection mode: AC charging mode: hiccup mode auto-recovery after fault condition is removed | |||||
Battery protection At low voltage | 9.5~11V | 20~22V | |||
Protection mode: cut off the output | |||||
Function | UPS introduction | long-term online floating charge to battery, high charging efficiency, battery can saturate to more than 90% ,cauto-stop harging when it"s full, prevent over charging. Effectively extend battery life, AC/battery auto switch, no switch time, no need human guard, cold-start ,when there is no AC input ,can use battery start UPS, Meet the user"s emergency needs | |||
Environment | Working temp,humidity | -10°C~+60°C,20%~90%RH | |||
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing | ||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||
Safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||
Others | Dimension | 129*98*38mm(L*W*H) | |||
Weight/packing | 0.52kg/45pcs/24kg/0.034m⊃3;/1.2CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |