Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware
- Model Number:
- AW-GEC2159
- Zone:
- 1/2Zones
- Usage:
- Fire Protection
- Alarm function:
- High Decibel Alram Sound
- Feature:
- FM200
- Color:
- Red
- Warranty:
- 1 Years
- Function:
- Fire suppression
- Company type:
- Manufactor
- Material:
- Iron
- Keyword:
- Fire Alarm Control Main Panel System
- Supply Ability:
- 1000 Piece/Pieces per Month
- Packaging Details
- Carton box
- Port
- ZHONGSHAN
- Lead Time:
Quantity(Pieces) 1 - 10 11 - 100 101 - 1000 >1000 Est. Time(days) 3 15 30 To be negotiated
The automatic extinguisher control panel AW-GEC2169 is designed execute European standards of EN54-2 and EN54-4 Fire Detection and Fire Alarm systems clause,and Control and Indicating Equipment EN12094-1 firefighting system standards.
EN54-2 Fire detection and fire alarm systemspart 2: control and indicating equipment
EN54-4 Fire detection and fire alarm systemspart 4: power supply equipment
EN12094-1 Fixed firefighting systems - Components for gas extinguishing systems
Requirements and test methods for electrical automatic control and delay devices
AW-GEC2169 with a new design, easy to operate, metal box opening and closing door with visible glass window, make the Panel running more safe.
The AW-GEC2169 automatic gas fire extinguisher panel has the following features:
The AW-GEC2169 automatic gas fire extinguisher panel has the following features:
Alarm input : two alarming zone signal input , 16 detectors could be connected to each zone
EM valve output : control the output of EM valve.
Panel output: line fault output / alarm output / fire extinguishing signal output/24VDC output
Power output: resettable 24VDC output, 200mA current limit protection
Automatic power switching: 220V AC power and standby battery power can be switched automatically.
The AW-GEC2169 automatic gas fire extinguisher panel has the following features:
Three levels of access control (view, operation, settings)
Fault detection with display: Real-time detect working condition of input, output, system, power, ground, fuse,and so on.
Manually disable function: Manually disable the Panel functions and zones devices.
Evacuation: Manually activate the fire alarm devices.
Silence operation: Manual silence the horns alarm and panel buzzer .
Delay time setting: You can manual set the Panel reseting time and Release delay time.
Panel Security Protection : outside cabinet with Visible glass window of opening and closing door .
tability: long-term rigorous testing before leaving the factory, the Panel is stable, safe and reliable;
AC INPUT | 220VAC 50HZ |
DC OUTPUT at Power Board | 24VDC (19V-28V) and 5VDC (4.9V-5.1V) |
Voltage for MCU | 5V for power board MCU, 3.3V for others |
Current at 24VDC from PSE | <450mA standby current |
Maximum current from PSE | 1.4A except batteries charge |
Batteries current | 1.85A maximum, current limited |
Auxiliary output | 24VDC, 200 mA max, current limited |
Extinguishant release delay time | Adjustable 0 to 60seconds(5 second steps) |
Imin, Imax.a and Imax.b according to EN54-2 | Imin=340mA, Imax.a=424mA, Imax.b=1.4A |
Batteries | 2*12V/ 2.3Ah sealed lead acid gel, self-regulated |
Battery replace Resistance | 1.6Ω±10% if needed |
Battery low-voltage protection | 21V |
The maximum and minimum electrical ratings for each input and output | Detectots / zone lines: 15.2V-28V Sounder lines:19-28V |
Fire protection/Fire routing lines:19-28VFault routing lines:18-28V | |
Detectors wiring allowed each zone | 16 points |
Max points (detector and MCP) per CIE | 32 points |
Zone alarm current | 6mA minimum/ 27mA maximum |
Sounder output | 200mA maximum |
Fire routing/ Fault routing | 200mA maximum each terminal |
Communication protocol | 2 wires RS485 bus system |
EOL resistor for zone, inputs(Except for main power) and outputs | 6.8K 1W |
Wires for 220V AC IN (recommended) | 16AWG |
Wires connect power board to interface board (recommended) | 20AWG |
Wire for main board wiring with interface board (recommended) | 28AWG |
Fuse on power board | 3A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow |
Fuses on interface board(general outputs) | 0.2A /250V Glass tube fuse 5*20(mm) Fast/quick blow [*5pcs] |
Fuse on interface board(Main Power) | 2A/ 250V Ceramic tube fuse 5*20(mm) Slowly blow |
Fuse on interface board(EM valve) | 1.5A/ 250V Glass tube fuse 5*20(mm) Fast/quick blow |
Environmental | Class A temperature range: -5 to 40°C (23~104°F) |
Humidity: 5 to 95% RH, non-condensing | |
Terminal blocks rating | All terminals rated for 12 to18 AWG |
(0.75 to 2.5 mm2) | |
Wires between interface board (Panel)and Detector(recommended) | 2-core shielded cable for 12 to18 AWG |
(0.75 to 2.5 mm2) |
1.Professional and experienced R&D team can offer free technical support and project support.
2.Prompt reply all-around and all-weather.
3.OEM/ODM services
4.One year warranty and technical maintenance.
Q1: Are you manufacturer?
A: (yes)
Q2: What is the lead time?
A: one week working day
Q3: How do you ship the goods and how long does it take arrive?
A: We usually ship by DHL, UPS, FedEx or by Air. 3-5 days after payment received.
Q4: Can I have a sample order?
A:Yes,we welcome sample order to test and check quality.
Q5: Do you offer OEM service?
A: Yes, we can design the things according to your request.
EMAIL.
sales09(@)asenware.com.
skype.
sales09_155
TEL.(Whatsapp/Wechat).
008613590128969
Customer Reviews total 0 items