Model | SP-100-5 | SP-100-12 | SP-100-24 | SP-100-48 |
Specification |
DC output voltage | 5V | 12V | 24V | 48V |
DC output current | 0-20A | 0-8.5A | 0-4.2A | 0-2.1A |
Wave and noise | 100mVp-p | 100mVp-p | 150mVp-p | 240mVp-p |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity | ±1% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 76% | 80% | 84% | 82% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
AC input voltage range | 85-132VAC /176~264VAC selected by swich 47~63Hz;248~370VDC |
Input current | 2A/115V 1A/230A |
AC INnrush current | Cold-start current30A/115V 60A/230V |
Leakage current | <1mA/240VAC |
Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery |
Over-voltage protection | 115%-135% |
Temperature coefficient | ±0.03%/°C(0-50°C) |
Setup rise hold up time | 1s,30ms,15ms |
Vibration | 10-500Hz,2G 10min,/1cycle,Period for60min,Each axes |
Withstand voltage | Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC |
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ |
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH |
Store temperature and humidity | -20°C~+85°C.10%~95%RH |
Overall dimension | 199×98×38mm |
Weight | 0.65Kgs |
Safety standards | UL1012 TUV EN6050(IEC950,UL1950)Approved |
EMC standards | CISPR22(EN55022),IEC801-2,3,4,IEC555-2 Verification |
Note: |
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity. |
2.Error.include the setting error,line stability and load stability.(Note:5). |
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. |
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. |
5.Load stability test:the load is from 0% to 100%. |
6.C2,3,6must be knocked down. |
Customer Reviews total 0 items