T5 t8 fluorescent light fixtures with emergency backup

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Emergency Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 17:50

  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
KUNSEN
Bulb Type:
LED
Battery Type:
Ni-Cd
Material:
Cold Rolled Steel Sheet
Usage:
emergency lighting
Certification:
ce, rohs
Specifications:
T5/28W, T8/36W
Production Name:
emergency light transformer
Part No.:
KS-F28N
Inner package material:
Cold Rolled Steel Sheet
Emergency time:
30~240mins
Input Voltage:
110V-265VAC,50HZ/60HZ
Output Current:
Self-adaption
U out in emergency:
1600V 23KHZ
Battery Pack:
4.8V
Product weight:
150g/pcs(no battery)
Inverter Size:
157x40x29mm
Supply Ability
Supply Ability:
20000 Set/Sets per Month the complete kit of emergency battery packs
Packaging & Delivery
Packaging Details
Standard exprot cartons
Port
foshan, guangzhou
Lead Time:
Quantity(Pieces)1 - 100101 - 10001001 - 5000 >5000
Est. Time(days)101525To be negotiated

T5 t8 fluorescent light fixtures with emergency backup

 

Fluorescent emergency inverter is special for fluorescent lamp, widely used in all kinds of fluorescent lamps including T5/T8/PL/2D/Ring etc...

 

Lamp is lit by ballast in normal working conditions, when main is failure, lamp is lit by battery via emergency inverter/module. 

 

Technically, it includes:

- Inverter/Module

- Battery pack

- Function testing button/Switch

- Performance indicative LED lamp

- All necessary accessories

Product information

 

 Product information

Specification:

 

 

Product Name

T5 t8 fluorescent emergency kits

Part No.

KS-F28N

Inverter Part No.

FEM0042C028N

Battery pack

4.8V

Input voltage    

85~275V/AC, 50/60HZ

U out in emergency

1600V 23KHZ

Current in emergency 

Self-adaption

Signaling     

Yes

Test button       

Yes

Duration     

0.5 ~5 hrs

Battery protection     

Yes

Operation temperature

-10°C ~ 50°C

Highest Surface Temperature

70°C

BLF                        

Upon request

Charging

24h after commissioning

Emergency / main-power emergency

Yes

Dimensions

Please be referred to drawing above

Suitable light source

T5/28W, T8/36W  Fluorescent lamp

Features:  

  • Intelligent automatic recharging function
  • Constant current battery charger
  • 1/2/3 hours emergency operation
  •  Led charge status display
  • Deep discharge protection to protect cells from over discharge
  • Facility for a Test switch to switch between Emergency and normal lighting function
  • Supplied with high brightness green/Red LED (manual test)
  • Complete with flex and plug
  • Push-wire terminal blocks for easy wiring installation
  • High quality of NI-CAD / NIMH rechargeable battery with 2 years of life
  • Small volume, convenient and flexible installation
  • Suitable for LED with external LED driver max 150W

Installation

Connection 1 is used for connecting to the life wire of the building electricity network before the switch, sensing if the life wire is "alive".

Connection 2 is used for connecting the neutral of the building electricity network

Connection 3 and 4 have a test switch (that is connected in series between the life connection 2 and electronic circuit of KUNSEN module).

Connection 5 (Positive +) and 6 (Negative -) for connection a LED indicator meaning the power and battery is connected correctly and the inverter is working.

Connection 7 (+) and 8 (-) are used to connect the battery for emergency operation

Connection 9 and 10 is connected to the output block of electronics ballast.

Connection 11 and 12 is connected to the other output block of electronic ballast

For those using magnetic ballast (Diagram 2), connection 9 is connected to the output block of magnetic ballast which is wired to "L" of building electricity and "SL"

Connection 10 and 11 is to connect Starter

Connection 12 is connected to Neutral Line.

Connection 13, 14, 15 and 16 are connected to the lamp.

 

More information, please click  

CONTACT US >

 

Product display

 

 Product display

 

More information, please click  

CONTACT US >

 

Hot sale

 

 Hot sale

Why choose us

 

 Why choose us

Emergency Battery backup system

It includes emergency inverter and efficient battery pack that can driver led lamp with internal & external LED driver for 30 minutes to 180 minutes during the mains failure. Automatically switch to emergency mode when mains is failure, led indicator indicates normal battery charging, press test button to simulate mains power off.

More details, please click  

CONTACT US >

 

Company overview

 

 Company overview

 Company information
Tel+86 ( 757 ) 63247196
Fax+86 ( 757 ) 81809980
Skype

kevinsmil

smiljames

E-mail

info@kunsen.com.cn

sales@kusen.com.cn

Whatsapp+86 13660080872
Wechat623518751
Webhttp://www.kunsen.com.cn
Add

Building 4, Zone F, New Lighting Source Industry Zone,

Luocun,Nanhai, Foshan, Guangdong, China 528200

More details, please click  

CONTACT US >

 

Production process

 

 Production process

 

Easiest assembly, high efficiency SMT is the most popular technology and process in the electronics assembly industry today.

With automation, high efficiency, reliable, strong anti-vibration, solder joint defect rate is low, good high-frequency characteristics.

Strict production process, all products have been tested. 100% pass rate.

 

More details, please click  

CONTACT US >

 

FAQ

 

 FAQ

 

Emergency battery pack FAQs

1. How to choose the right emergency battery packs?

Firstly, please let us know what kind of your lighting you use, such as LED tube, LED panel, downlight, CFL, Fluorescent, halogen or LED strip etc...

Secondly, we"d like to know power of your lamp (Watts)

Thirdly, we"d like to know your local mains voltage, 220V or 110V or others

Fourthly, we need to know how long duration you required, such as 0.5 hour, 1 hour, 2 hours or 3 hours, or more

Fifthly, what kinds of battery do you prefered? such as NiCad, Nimh, or Lithium etc..

Sixthly, do you install the emergency battery pack into a box or outside? If you have any requirements on size?

After we have all information above, then the best solution will be offered to you.

or contact with our sales directly about your needs.

 

2. What is our main products of your emergency battery packs?

Our main products include:

1. Emergency kit with full emergency power for lights with AC220V or 220-310V DC or 100-150V DC output voltage, emergency power is from 3W to 300w with different types.

2. Constant current output EM kit for LED with external driver, such as LED down light, LED panel etc. Emergency power can be customized according to customer"s requirements. Light output in emergency operation = (LED current in emergency operation)/(LED current in mains operation)x(light output in mains operation).

3. Constant voltage 6V/12v/24v for LED strip and quartz halogen, emergency power is 10W to 50W.

4. Constant Power EM kit with 5W or 10W emergency power.

5. EM kit for T5/T8/PL fluorescent lamp from 8w to 70W, emergency power is from 4W to 8W.

6. EM module with integrated LED driver can be work for LED board of 8-24W. It is easy plug and play for installation.

 

3. It need be charged for the first time usage after installation?

Yes, the battery packs must be charged over 24 hours after installation

 

4. Can EM kit work with any kinds of lights?

No, we have different EM kit for different lamps, please reference to " How to choose the right emergency battery packs".

 

5. How to know you choose high temperature battery or regular temperature battery?

The high temperature battery can be trickle charged well even if the emergency kit is in high temperature due to insufficient radiating caused by the lights working for long time. While regular temperature battery stop charging in high temperature that result in emergency light failed to work. We recommend to use high temperature battery for EM kit.

 

6. Are the emergency modules with over charging protection and discharging protection?

The battery is being charge all along when mains is working, and the charging current will be decreased based on the capacity status of battery packs during charging. When battery pack is changing enough, the charging current is very small, and need not over voltage protection, but on discharging operation the emergency module set a cutting voltage to protect over discharging.

 

7. How EM kit work?

When the normal supply of AC power fails, the emergency kit senses the power failure and immediately switches to the emergency mode to illuminate lamps. When AC power is restored, the emergency ballast returns to the charging mode until the next power failure or emergency situation. The battery fully recharges within 24 hours.

 

8. Do you offer OEM or ODM service?

Yes, we have our Brand "KUNSEN", and OEM and ODM services are welcome too. We can do customer"s design, box and labels.

 

BACK TO HOME PAGE >>

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links