- Place of Origin:
- Guangdong, China
- Brand Name:
- Sanforce
- Bulb Type:
- LED
- Battery Type:
- Ni-Cd
- Material:
- Plastic
- Usage:
- emergency lighting
- Certification:
- CE
- Specifications:
- 15W
- Warranty(Year):
- 3-YEAR
- Emergency Power:
- 15W
- Emergency time:
- 1hours
- Charging time:
- 24 hours
- The input voltage:
- 85~265VAC
- Name:
- LED emergency module
- Battery:
- Ni-CD
- Function:
- emergency lighting
- Product size:
- 155mmx40mmx30mm
- Light Source:
- LED
- Output voltage:
- 15-90V
Packaging & Delivery
- Selling Units:
- Single item
- Single package size:
- 23X15X8.5 cm
- Single gross weight:
- 1.5 kg
- Package Type:
- Conventional packing or the customer request
- Picture Example:
- Lead Time:
Quantity(Piece) 1 - 500 501 - 1000 1001 - 2000 >2000 Est. Time(days) 10 15 20 To be negotiated
LED power supply with waterproof box is designed specifically to suit Constant Current type LEDs and ciruits.Utilizing DC/DC switcher circuitry.Product is compatible with wide range of LED fixture ideal for LED panel light light,LED down light and many others with extermal LED driver and low voltage(6~90),emergency output power 5%~100%.
Inner package material | Retardan White Plastic |
Charging power | AC85V~AC265V,50HZ/60HZ |
Emergency time | 30~180mins |
Charging time | 24Hours |
Emergency output current | 20~800mA |
Battery voltage | 3.6~12V |
Battery capacity | 500~8000mAh |
Emergency output voltage | DC3.6V~150V |
Inverter dimension | 155*40*30mm |
Desription
Sanforce Emergency inverter module allow the LED fixtures to meet requirement for emergency illumination.
Designed especially for Constant Current type LEDs and circuits. Utilizing DC/DC switcher circuitry. Product is compatible with wide range of LED fixture ideal for LED panel light, LED down light,LED ceiling light and many others with external LED driver and low voltage(6-90V).
Features
- IC controlled Dual rate Charger for energy savings.
- Short circuit protection at battery terminals.
- Battery reverse protection functionality
- Charge indicator and test button. The light fittings guarantee safety of people in buildings open to the general public.
- Automatically actuated in the event of power cuts, these devices (kit + light fitting) offer a good luminous flux to facilitate the evacuation.
- Comply with European standards EN 61 347-2-7 and offer a high level of quality and safety meeting the various prevailing regulations.
- Dial the code to suitable voltage of luminiares.1 or 3 h rated duration.
- Constant current output,emergency power is vaired by lighting output voltage, automatically match with the lighting setting to provide best illuminations.
LED Inverter module |
|
LED Inverter module accessory |
LED indicator - It displays the working state and determines whether there is an exception. - Either red or green indicator bulb option - Indicator light on: charging mode or battery fully charged. - Indicator light off: Battery is not connected or Battery is defective Test switch - Under normal working condition, the lamp will enter the discharge state by pressing the test switch. - Release the switch and automatically return to the charging state. - In the discharge mode, the discharge will be switched off according to the test switch for more than 3 seconds |
LED Inverter module install |
Installed on the back of the panel requires safety and fixation. - Only professional people (e.g. electrical engineer) can wire it. - Please confirm that the electrical paramters of this product match with the luminaire. - Please check the wiring method carefully before installation. - Please power off mains supply before installation, and confirm the wiring is correct, then connect the battery, the last step is to turn on mains supply. |
LED conversion kit Attention |
To guarantee the rated discharge time, please charge the battery for more than 24 hours. Please ensure that the voltage is 80% higher than the rated voltage, less than 110% of the highest rated voltage. - Charge and discharge cycle needs to be done at least once every three months, and the continuous charging time can not exceed 3 months. - Warranty Warranty: 3 years Except for the following circumstances 1) Improper installation or operation. 2) Misuse 3) Abuse 4) Unauthoruzed or improper repair alteration. 5) Accident or negligence in use, storage, transportation. |
THE FOLLOWING SCENARIO
FOR THE APPLICATION OF GOODS
Sanforce is the leading manufacturer of LED emergency pack in China,with more than 10 years experience in the led light emergency power pack development,manufacture and marketing.Our products have been sold to more than 30 countries and regions.
Supported by the great influence and reputation of Sanforce LED emergency pack in the overseas market, cooperate with Sanforce strongly,we believe that you will achieve great success in your national or regional market soon,and reach the win-win success.
Why choose us |
Excellent Quality Assurance We have strict quality policy and effective QC system to ensure everything is under control, from design to process, from parts manufacturing to finished goods testing. Meanwhile, Our workmen are stabilized and skillful, Most of them work at our factory for more than 5 years, They are professional and have full experience to produce the emergency units
Rich Resource Support Manual and videos to guide the operation process, training service, technical support and warranty service—all to enrich your knowledge on emergency conversion kit
Multiple Customized Solution Emergency kit solutions vary in respect to lighting applications and specific demands. We are capable to provide you with the excellent embodiment.
|
Emergency battery pack FAQs
1. How to choose the right emergency battery packs?
Firstly, please let us know what kind of your lighting you use, such as LED tube, LED panel, downlight, CFL, Fluorescent, halogen or LED strip etc...
Secondly, we"d like to know power of your lamp (Watts)
Thirdly, we"d like to know your local mains voltage, 220V or 110V or others
Fourthly, we need to know how long duration you required, such as 0.5 hour, 1 hour, 2 hours or 3 hours, or more
Fifthly, what kinds of battery do you prefered? such as NiCad, Nimh, or Lithium etc..
Sixthly, do you install the emergency battery pack into a box or outside? If you have any requirements on size?
After we have all information above, then the best solution will be offered to you.
or contact with our sales directly about your needs.
2. What is our main products of your emergency battery packs?
Our main products include:
A. Emergency kit with full emergency power for lights with AC220V or 220-310V DC or 100-150V DC output voltage, emergency power is from 3W to 300w with different types.
B. Constant current output EM kit for LED with external driver, such as LED down light, LED panel etc. Emergency power can be customized according to customer"s requirements. Light output in emergency operation = (LED current in emergency operation)/(LED current in mains operation)x(light output in mains operation).
C. Constant voltage 6V/12v/24v for LED strip and quartz halogen, emergency power is 10W to 50W.
D. Constant Power EM kit with 5W or 10W emergency power.
E. EM kit for T5/T8/PL fluorescent lamp from 8w to 70W, emergency power is from 4W to 8W.
F. EM module with integrated LED driver can be work for LED board of 8-24W. It is easy plug and play for installation.
3. It need be charged for the first time usage after installation?
Yes, the battery packs must be charged over 24 hours after installation
4. Can EM kit work with any kinds of lights?
No, we have different EM kit for different lamps, please reference to " How to choose the right emergency battery packs".
5. How to know you choose high temperature battery or regular temperature battery?
The high temperature battery can be trickle charged well even if the emergency kit is in high temperature due to insufficient radiating caused by the lights working for long time. While regular temperature battery stop charging in high temperature that result in emergency light failed to work. We recommend to use high temperature battery for EM kit.
6. Are the emergency modules with over charging protection and discharging protection?
The battery is being charge all along when mains is working, and the charging current will be decreased based on the capacity status of battery packs during charging. When battery pack is changing enough, the charging current is very small, and need not over voltage protection, but on discharging operation the emergency module set a cutting voltage to protect over discharging.
7. How EM kit work?
When the normal supply of AC power fails, the emergency kit senses the power failure and immediately switches to the emergency mode to illuminate lamps. When AC power is restored, the emergency ballast returns to the charging mode until the next power failure or emergency situation. The battery fully recharges within 24 hours.
8. Do you offer OEM or ODM service?
Yes, we have our Brand "KUNSEN", and OEM and ODM services are welcome too. We can do customer"s design, box and labels.
Packaging:Standard export carton or customized
More information, please click |