Fire alarm control panel:
SR-P01-4 4 zones conventional fire alarm control panel
SR-P01-8 8 zones conventional fire alarm control panel
SR-P01-16 16 zones conventional fire alarm control panel
The SR-P01 Series Conventional Fire Alarm Control Panel is 220VAC, 50 Hz., four to sixteen-zone(Selected by the customer), Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly cost-effective SR-P01 Series can be used in a variety of low- to mid-sized applications.
Main features:
Four, Eight, Sixteen Zone Style B (Class B) Initiating Device Circuits (IDCs), All zones accept
two-wire smoke detectors and any normally-open contact devices.
Two Supervisory Input with DC12V output, ideal to connect security alarm devices.
Three General Alarm, Trouble and Supervisory, Form A Relay Output.
One, Two, Four Built-in Sound Output, Style Y (Class B) Notification Appliance (Signal) Circuits
(NACs), NACs may be programmed: Silenceable or Non-Silenceable.
3.0 amps of total system power. Resettable DC24V & Non-resettable DC24V Output.
Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode.
RS485 Communication Port (optional).
Automatic/Manual mode can be programmed.
Disable/Enable control per Zone (IDC) can be programmed.
Disable/Enable Sound Output(NACs) can be programmed.
Technical Parameters
AC Power | 220VAC, 50 Hz. |
Battery | Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge |
Maximum battery charger capacity | 18AH battery |
NOTE | Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box |
Total DC24V system power | 3.0 amps |
Maximum current per NAC | 1.25 amps |
Maximum battery charging capability | 18 AH |
Resettable four-wire smoke detector power output. | yes |
Non-resettable power output. | yes |
Integral Form-A Alarm, Trouble and Supervisory relays, rated at | 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive) |
This fire alarm control panel can Match any 2/4-wire smoke heat detector,strobe siren,fire bell,manual call point ect
smoke detector | 2 wire, 4 wire optiona, photoeletrci type |
heat detector | 2 wire, 4 wire optional, rate of rise or fixed temeparture |
strobe siren | wired type, with or without strobe |
fire bell | wired type, indoor or outdoor type |
manual call point | resettable type or breaking glass type optional |
Not only the alarm control panel we have, but also we offer all kinds of detectors you want, we are looking forward to your inquiry, thank you!
Payment terms:L/C,D/A,D/P,T/T, Western Union,Paypal ect
Delivery time :Normal order within 7 days,bulk order 10-15 days
Packing:Neutral paper box and paper carton
Tel: 86- 755-89571625
For product pricing, customiztion, or other inquiries
Contact Supplier
Customer Reviews total 0 items