IG541 Clean agent fire extinguishing system,fire protection system

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-16 21:09

  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
welfare
Mixtured gas:
52% 40% 40% nitrogen, argon, carbon dioxide mixture
Consist:
fire detection and alarm , fire fighting , pipe net work
stored condition:
20 ℃ storage pressure: 15 MPa
stored cylinder:
80 ltr, 90ltr,16.8 Kg
maximum working pressure:
50 ℃) : 17.2 MPa
Start Model:
electircal , pneumatic and manual
Supply Ability
Supply Ability:
100 Set/Sets per Quarter
Packaging & Delivery
Packaging Details
wooden carton
Port
Ningbo
Lead Time:
Quantity(Sets)1 - 10 >10
Est. Time(days)10To be negotiated
Product Description

 

Company Information

 

FAQ
 

IG541 Fire Extinguishing system

 

1. System introduction

 

mixed gas IG541 is made up of 52% 40% 40% nitrogen, argon, carbon dioxide mixture of proportion by the steric (physical) way,in a short period of time after discharge to the protection zone can make protection zone of 

the oxygen concentration is reduced to support combustion under 12.5%, and burning fire smothering action 

implementation. , on the other hand, according to the longterm medical experiments prove that the human 

body in 12.5% oxygen concentration and the concentration of 2% to 5% carbon dioxide environment breath, 

brain of oxygen and at normal atmospheric environment (21% oxygen concentration and co2 concentration 

0.03%) gained by the oxygen content is the same. This is because in hypoxia environment, if carbon dioxide 

concentrations increased to 2% 5% can make people breathing deepen and accelerate, in unit time make the person obtains enough oxygen to brain cells. Mixed gas IG541, 8% of the carbon dioxide gas is artificially 

make the protection zone of rising carbon dioxide levels to meet the anoxic environment breathing for 2% 5%, and won"t cause harm to human body.

 

 

1.2 system structure 

 

1.2.1 unit independent system 

 

 

 

 

 

2.Unique advantages

 

1. Agent completely by nature exists in the atmosphere of inert gas, after the discharge to the environment completely without damage; 

2.Under prescribed fire extinguishing concentration is completely harmless to human body, can stay in one 

place safely use;

3. Fire extinguishing agent sources, can ensure long-term use;

4.Fire extinguishing agent is completely composed of inert gas, does not cause protection zone temperature fell sharply after discharge, the precision equipment and other valuable belongings without any harm;

5. Because of the storage pressure is higher, compared with other fire extinguishing system can transport a 

long distance, 

6.Under the combined distribution system methods can connect more protection zone, thus saving investment.

 

3.System main technical parameters 

 

20 °C storage pressure: 15 MPa 

fire extinguishing agent storage bottles of specifications/filling quantity: 80 l / 80 l / 16.8 Kg, 16.8 Kg 

maximum working pressure (50 °C) : 17.2 MPa 1 start mode: magnetic start, mechanical emergency start 

electromagnetic drive air pressure: 6.0 + / - 1.0 MPa (20 °C) 

electromagnetic drive starting power: DC24V / 1.5 A 1.2.7 agent application time: 60 s or less

protection zone temperature: 0 °C to 50 °C 1.2.9 store between bottle temperature: 0 °C to 50 °C

 

4.System operation principle 

 

1. mixed gas IG541 automatic fire extinguishing system with automatic, manual, mechanical emergency operation three kinds of start ways. 

2.condition automatically, if a protection zone occurs with smoke (or temperature), the protection zone, smoke fire detector (or temperature) movement and the fire alarm controller into a single fire alarm, fire alarm 

controller that is into the single state, drive electric alarm signal of a single fire alarm at the same time, this 

time will not start the fire extinguishing system of control signals. As the spread of fire protection zone, the 

temperature rising smoke (or increase), the other primary circuit heat or smoke fire detector, the controller into a single fire signal, the controller immediately confirm that there is a fire, at the same time signal composite 

fire alarm and linkage (closed air conditioning, ventilation device and fire damper, fire doors, fire shutter, etc.). After 30 seconds of time delay, tThe controller output signal to start the fire extinguishing system, cast into the fire extinguishing agent through the pipeline to implement fire protection zone. Controller receives the 

feedback signal of pressure signal after the show bright deflated lights, avoid straying. In manual mode, alarm controller only when the fire broke out a fire alarm signals and does not produce linkage. 

3. requires automatic or manual mode, the personnel on duty after confirmation of fire, press the alarm controller on the front panel or the scene of the "emergency start" button to start the fire extinguishing system 

immediately. Before discharge control signal output, press the alarm controller on the front panel or the 

scene of the "emergency stop" button, the system will not discharge signal output.

 